Total
10 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-4744 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2024-05-17 | 10.0 HIGH | 9.8 CRITICAL |
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability. | |||||
CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2023-08-10 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | |||||
CVE-2023-38935 | 1 Tenda | 10 Ac10, Ac10 Firmware, Ac1206 and 7 more | 2023-08-10 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. | |||||
CVE-2023-38931 | 1 Tenda | 16 Ac10, Ac10 Firmware, Ac1206 and 13 more | 2023-08-10 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. | |||||
CVE-2023-33675 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. | |||||
CVE-2023-33673 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | |||||
CVE-2023-33672 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | N/A | 7.5 HIGH |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. | |||||
CVE-2023-33671 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function. | |||||
CVE-2023-33670 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function. | |||||
CVE-2023-33669 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2023-06-12 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function. |