Filtered by vendor Tenda
Subscribe
Total
746 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-46369 | 1 Tenda | 2 W18e, W18e Firmware | 2023-11-01 | N/A | 9.8 CRITICAL |
Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function. | |||||
CVE-2023-40830 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-10-06 | N/A | 9.8 CRITICAL |
Tenda AC6 v15.03.05.19 is vulnerable to Buffer Overflow as the Index parameter does not verify the length. | |||||
CVE-2023-42320 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2023-09-21 | N/A | 9.8 CRITICAL |
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. | |||||
CVE-2021-40546 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 4.9 MEDIUM |
Tenda AC6 US_AC6V4.0RTL_V02.03.01.26_cn.bin allows attackers (who have the administrator password) to cause a denial of service (device crash) via a long string in the wifiPwd_5G parameter to /goform/setWifi. | |||||
CVE-2023-40844 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'formWifiBasicSet.' | |||||
CVE-2023-40839 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADF3C' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADF3C" function to execute commands. | |||||
CVE-2023-40840 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "fromGetWirelessRepeat." | |||||
CVE-2023-40841 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "add_white_node," | |||||
CVE-2023-40842 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler." | |||||
CVE-2023-40843 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "sub_73004." | |||||
CVE-2023-40845 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks. | |||||
CVE-2023-40847 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check. | |||||
CVE-2023-40848 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-07 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858." | |||||
CVE-2023-40837 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-01 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADD50' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADD50" function to execute commands. | |||||
CVE-2023-41561 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2023-09-01 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. | |||||
CVE-2023-40838 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2023-09-01 | N/A | 9.8 CRITICAL |
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability. | |||||
CVE-2023-41560 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2023-09-01 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. | |||||
CVE-2023-41562 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2023-09-01 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. | |||||
CVE-2023-41563 | 1 Tenda | 4 Ac5, Ac5 Firmware, Ac9 and 1 more | 2023-09-01 | N/A | 9.8 CRITICAL |
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. | |||||
CVE-2023-41559 | 1 Tenda | 6 Ac5, Ac5 Firmware, Ac7 and 3 more | 2023-09-01 | N/A | 9.8 CRITICAL |
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. |