Filtered by vendor Mitsubishielectric
Subscribe
Total
156 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-5544 | 1 Mitsubishielectric | 2 Iu1-1m20-d, Iu1-1m20-d Firmware | 2020-03-19 | 7.5 HIGH | 9.8 CRITICAL |
Null Pointer Dereference vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet. | |||||
CVE-2020-5546 | 1 Mitsubishielectric | 2 Iu1-1m20-d, Iu1-1m20-d Firmware | 2020-03-19 | 5.8 MEDIUM | 8.8 HIGH |
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows an attacker on the same network segment to stop the network functions or execute malware via a specially crafted packet. | |||||
CVE-2020-5543 | 1 Mitsubishielectric | 2 Iu1-1m20-d, Iu1-1m20-d Firmware | 2020-03-18 | 7.5 HIGH | 9.8 CRITICAL |
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions or execute malware via a specially crafted packet. | |||||
CVE-2020-5531 | 1 Mitsubishielectric | 10 Mi5122-vw, Mi5122-vw Firmware, Q24dhccpu-v and 7 more | 2020-03-04 | 7.5 HIGH | 9.8 CRITICAL |
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors. | |||||
CVE-2019-13555 | 1 Mitsubishielectric | 20 L02\/06\/26cpu, L02\/06\/26cpu-cm, L02\/06\/26cpu-cm Firmware and 17 more | 2019-11-18 | 4.3 MEDIUM | 5.9 MEDIUM |
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules. | |||||
CVE-2019-14926 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2019-10-30 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites. | |||||
CVE-2019-14928 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2019-10-30 | 3.5 LOW | 5.4 MEDIUM |
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is SerialInitialModemString in the index.php page. | |||||
CVE-2019-14929 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2019-10-30 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An unauthenticated user can obtain the exposed password credentials to gain access to the following services: DDNS service, Mobile Network Provider, and OpenVPN service. | |||||
CVE-2019-14930 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2019-10-30 | 10.0 HIGH | 9.8 CRITICAL |
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.) | |||||
CVE-2019-14931 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2019-10-30 | 10.0 HIGH | 9.8 CRITICAL |
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's system shell. Functionality in mobile.php provides users with the ability to ping sites or IP addresses via Mobile Connection Test. When the Mobile Connection Test is submitted, action.php is called to execute the test. An attacker can use a shell command separator (;) in the host variable to execute operating system commands upon submitting the test data. | |||||
CVE-2019-14925 | 2 Inea, Mitsubishielectric | 4 Me-rtu, Me-rtu Firmware, Smartrtu and 1 more | 2019-10-30 | 4.0 MEDIUM | 6.5 MEDIUM |
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment. | |||||
CVE-2019-10976 | 1 Mitsubishielectric | 2 Electric Fr Configurator2, Electric Fr Configurator2 Firmware | 2019-10-09 | 4.3 MEDIUM | 5.5 MEDIUM |
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files. | |||||
CVE-2017-9638 | 1 Mitsubishielectric | 1 E-designer | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash. | |||||
CVE-2017-9636 | 1 Mitsubishielectric | 1 E-designer | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash. | |||||
CVE-2017-9634 | 1 Mitsubishielectric | 1 E-designer | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash. | |||||
CVE-2013-2817 | 1 Mitsubishielectric | 1 Mc-worx Suite | 2014-02-24 | 9.3 HIGH | N/A |
An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click. |