Filtered by vendor Siemens
Subscribe
Total
1761 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-7583 | 1 Siemens | 1 Automation License Manager | 2020-08-21 | 4.6 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0.8). The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing. | |||||
CVE-2020-15781 | 1 Siemens | 2 Sicam A8000, Sicam A8000 Firmware | 2020-08-21 | 6.8 MEDIUM | 9.6 CRITICAL |
A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application. | |||||
CVE-2020-10055 | 1 Siemens | 2 Desigo Consumption Control, Desigo Consumption Control Compact | 2020-08-21 | 9.3 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in Desigo CC (V4.x), Desigo CC (V3.x), Desigo CC Compact (V4.x), Desigo CC Compact (V3.x). Affected applications are delivered with a 3rd party component (BIRT) that contains a remote code execution vulnerability if the Advanced Reporting Engine is enabled. The vulnerability could allow a remote unauthenticated attacker to execute arbitrary commands on the server with SYSTEM privileges. | |||||
CVE-2020-7592 | 1 Siemens | 9 Simatic Hmi Basic Panels 1st Generation, Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Comfort Panels and 6 more | 2020-07-22 | 3.3 LOW | 6.5 MEDIUM |
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information. | |||||
CVE-2020-7593 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2020-07-22 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (V1.81.01 - V1.81.03), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.01), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.02). A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacker could send a specially crafted HTTP request to cause a memory corruption, potentially resulting in remote code execution. | |||||
CVE-2020-7584 | 1 Siemens | 4 Simatic S7-200 Smart Sr Cpu, Simatic S7-200 Smart Sr Cpu Firmware, Simatic S7-200 Smart St Cpu and 1 more | 2020-07-17 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions >= V2.2 < V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation. | |||||
CVE-2020-7577 | 1 Siemens | 1 Opcenter Execution Core | 2020-07-17 | 5.5 MEDIUM | 8.1 HIGH |
A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to the back-end server. The exploit of this vulnerability could be used to read, and potentially modify application data to which the user has access to. | |||||
CVE-2020-7578 | 1 Siemens | 1 Opcenter Execution Core | 2020-07-17 | 5.5 MEDIUM | 8.1 HIGH |
A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Authenticated users could have access to resources they normally would not have. This vulnerability could allow an attacker to view internal information and perform unauthorized changes. | |||||
CVE-2020-10039 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 6.8 MEDIUM | 8.1 HIGH |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data. | |||||
CVE-2020-10040 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with local access to the device might be able to retrieve some passwords in clear text. | |||||
CVE-2020-10042 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network. | |||||
CVE-2020-10044 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device. | |||||
CVE-2020-10045 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 6.8 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application. | |||||
CVE-2020-10038 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication. | |||||
CVE-2020-10037 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information. | |||||
CVE-2020-10041 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 4.3 MEDIUM | 6.1 MEDIUM |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user. | |||||
CVE-2020-10043 | 1 Siemens | 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more | 2020-07-15 | 4.3 MEDIUM | 6.1 MEDIUM |
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. | |||||
CVE-2019-10930 | 1 Siemens | 26 6md85, 6md86, 6md89 and 23 more | 2020-06-10 | 6.4 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system. | |||||
CVE-2012-3017 | 1 Siemens | 4 Simatic S7-400 Cpu 414-3 Pn\/dp, Simatic S7-400 Cpu 416-3 Pn\/dp, Simatic S7-400 Cpu 416f-3 Pn\/dp and 1 more | 2020-04-13 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets. | |||||
CVE-2012-3016 | 1 Siemens | 6 Simatic S7-400 Cpu 412-2 Pn, Simatic S7-400 Cpu 414-3 Pn\/dp, Simatic S7-400 Cpu 414f-3 Pn\/dp and 3 more | 2020-04-13 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets. |