CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-19288 1 Siemens 1 Xhq 2020-12-15 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.
CVE-2020-15791 1 Siemens 28 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 312 Firmware, Simatic S7-300 Cpu 314 and 25 more 2020-12-14 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
CVE-2018-4833 1 Siemens 18 Rfid 181-eip, Rfid 181-eip Firmware, Ruggedcom Wimax and 15 more 2020-12-14 5.8 MEDIUM 8.8 HIGH
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
CVE-2020-7590 1 Siemens 2 Dca Vantage Analyzer, Dca Vantage Analyzer Firmware 2020-10-29 4.6 MEDIUM 6.8 MEDIUM
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device.
CVE-2020-15797 1 Siemens 2 Dca Vantage Analyzer, Dca Vantage Analyzer Firmware 2020-10-28 7.2 HIGH 6.8 MEDIUM
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Improper Access Control could allow an unauthenticated attacker to escape from the restricted environment (“kiosk mode”) and access the underlying operating system. Successful exploitation requires direct physical access to the system.
CVE-2019-8276 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-22 5.0 MEDIUM 7.5 HIGH
UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
CVE-2019-8274 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-22 7.5 HIGH 9.8 CRITICAL
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
CVE-2019-8273 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-22 7.5 HIGH 9.8 CRITICAL
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
CVE-2019-8272 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-22 7.5 HIGH 9.8 CRITICAL
UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
CVE-2020-15793 1 Siemens 1 Desigo Insight 2020-10-21 5.8 MEDIUM 5.4 MEDIUM
A vulnerability has been identified in Desigo Insight (All versions). The device does not properly set the X-Frame-Options HTTP Header which makes it vulnerable to Clickjacking attacks. This could allow an unauthenticated attacker to retrieve or modify data in the context of a legitimate user by tricking that user to click on a website controlled by the attacker.
CVE-2019-8271 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-19 7.5 HIGH 9.8 CRITICAL
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
CVE-2019-8269 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-19 5.0 MEDIUM 7.5 HIGH
UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.
CVE-2019-8268 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-19 7.5 HIGH 9.8 CRITICAL
UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.
CVE-2019-8258 2 Siemens, Uvnc 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more 2020-10-19 7.5 HIGH 9.8 CRITICAL
UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.
CVE-2019-6580 1 Siemens 5 Siveillance Video Management Software 2017 R2, Siveillance Video Management Software 2018 R1, Siveillance Video Management Software 2018 R2 and 2 more 2020-10-16 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-6581 1 Siemens 5 Siveillance Video Management Software 2017 R2, Siveillance Video Management Software 2018 R1, Siveillance Video Management Software 2018 R2 and 2 more 2020-10-16 6.5 MEDIUM 8.8 HIGH
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13921 1 Siemens 1 Simatic Winac Rtx \(f\) 2010 2020-10-16 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions < SP3 Update 1). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is sent to the executing service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the service provided by the software.
CVE-2019-13929 1 Siemens 1 Simatic It Uadm 2020-10-16 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-6579 1 Siemens 1 Spectrum Power 4 2020-10-16 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13945 1 Siemens 32 S7-200 Smart, S7-200 Smart Firmware, Simatic S7-1200 and 29 more 2020-10-09 4.6 MEDIUM 6.8 MEDIUM
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.