Vulnerabilities (CVE)

Filtered by vendor Mitsubishielectric Subscribe
Total 156 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-5653 1 Mitsubishielectric 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more 2020-11-10 7.5 HIGH 9.8 CRITICAL
Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVE-2020-5655 1 Mitsubishielectric 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more 2020-11-10 5.0 MEDIUM 7.5 HIGH
NULL pointer dereferences vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products via a specially crafted packet.
CVE-2020-5656 1 Mitsubishielectric 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more 2020-11-10 7.5 HIGH 9.8 CRITICAL
Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVE-2020-5657 1 Mitsubishielectric 10 Melsec Iq-rd81dl96, Melsec Iq-rd81dl96 Firmware, Melsec Iq-rd81mes96n and 7 more 2020-11-10 3.3 LOW 6.5 MEDIUM
Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows unauthenticated attackers on adjacent network to stop the network functions of the products via a specially crafted packet.
CVE-2020-16226 1 Mitsubishielectric 186 Conveyor Tracking Application Apr-ntr12fh, Conveyor Tracking Application Apr-ntr20fh\(n\=1\,2\), Conveyor Tracking Application Apr-ntr3fh and 183 more 2020-10-22 7.5 HIGH 9.8 CRITICAL
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
CVE-2019-10972 1 Mitsubishielectric 1 Electric Fr Configurator2 2020-10-02 7.1 HIGH 5.5 MEDIUM
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.
CVE-2019-10977 1 Mitsubishielectric 2 Qj71e71-100, Qj71e71-100 Firmware 2020-10-02 7.8 HIGH 7.5 HIGH
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.
CVE-2020-12011 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2020-07-29 7.5 HIGH 9.8 CRITICAL
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition or allow remote code execution. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; GenBroker32 version 9.5 and prior.
CVE-2020-12009 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2020-07-29 5.0 MEDIUM 7.5 HIGH
A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
CVE-2020-12015 2 Iconics, Mitsubishielectric 11 Bizviz, Energy Analytix, Facility Analytix and 8 more 2020-07-22 5.0 MEDIUM 7.5 HIGH
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
CVE-2020-5602 1 Mitsubishielectric 20 Cpu Module Logging Configuration Tool, Cw Configurator, Em Configurator and 17 more 2020-07-14 5.0 MEDIUM 7.5 HIGH
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.
CVE-2020-5595 1 Mitsubishielectric 4 Coreos, Got2000 Gt23, Got2000 Gt25 and 1 more 2020-07-14 7.5 HIGH 9.8 CRITICAL
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a buffer overflow vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVE-2020-5596 1 Mitsubishielectric 4 Coreos, Got2000 Gt23, Got2000 Gt25 and 1 more 2020-07-14 5.0 MEDIUM 7.5 HIGH
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) does not properly manage sessions, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVE-2020-5597 1 Mitsubishielectric 4 Coreos, Got2000 Gt23, Got2000 Gt25 and 1 more 2020-07-14 5.0 MEDIUM 7.5 HIGH
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a null pointer dereference vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
CVE-2020-5603 1 Mitsubishielectric 20 Cpu Module Logging Configuration Tool, Cw Configurator, Em Configurator and 17 more 2020-07-09 5.0 MEDIUM 7.5 HIGH
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors.
CVE-2020-5594 1 Mitsubishielectric 10 Melsec-fx, Melsec-fx Firmware, Melsec-l and 7 more 2020-07-01 7.5 HIGH 9.8 CRITICAL
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
CVE-2020-13238 1 Mitsubishielectric 42 Melsec Iq-r00cpu, Melsec Iq-r00cpu Firmware, Melsec Iq-r01cpu and 39 more 2020-06-23 7.8 HIGH 7.5 HIGH
Mitsubishi MELSEC iQ-R Series PLCs with firmware 33 allow attackers to halt the industrial process by sending an unauthenticated crafted packet over the network, because this denial of service attack consumes excessive CPU time. After halting, physical access to the PLC is required in order to restore production.
CVE-2020-5527 1 Mitsubishielectric 92 Cr800-q, Cr800-q Firmware, Fx3g and 89 more 2020-04-07 5.0 MEDIUM 7.5 HIGH
When MELSOFT transmission port (UDP/IP) of Mitsubishi Electric MELSEC iQ-R series (all versions), MELSEC iQ-F series (all versions), MELSEC Q series (all versions), MELSEC L series (all versions), and MELSEC F series (all versions) receives massive amount of data via unspecified vectors, resource consumption occurs and the port does not process the data properly. As a result, it may fall into a denial-of-service (DoS) condition. The vendor states this vulnerability only affects Ethernet communication functions.
CVE-2020-5542 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2020-03-19 7.5 HIGH 9.8 CRITICAL
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
CVE-2020-5545 1 Mitsubishielectric 2 Iu1-1m20-d, Iu1-1m20-d Firmware 2020-03-19 7.5 HIGH 9.8 CRITICAL
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to bypass access restriction and to stop the network functions or execute malware via a specially crafted packet.