Vulnerabilities (CVE)

Filtered by vendor Abb Subscribe
Total 125 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-8474 1 Abb 1 800xa Base System 2020-04-30 4.6 MEDIUM 7.8 HIGH
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
CVE-2019-19105 2 Abb, Busch-jaeger 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more 2020-04-29 2.1 LOW 5.5 MEDIUM
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
CVE-2019-10995 1 Abb 16 Cp651, Cp651-web, Cp651-web Firmware and 13 more 2020-01-24 5.8 MEDIUM 8.8 HIGH
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.
CVE-2019-18995 1 Abb 1 Pb610 Panel Builder 600 2019-12-31 5.0 MEDIUM 5.3 MEDIUM
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.
CVE-2019-18994 1 Abb 1 Pb610 Panel Builder 600 2019-12-31 3.5 LOW 6.5 MEDIUM
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.
CVE-2018-5477 1 Abb 1 Netcadops 2019-10-09 5.0 MEDIUM 5.8 MEDIUM
An Information Exposure issue was discovered in ABB netCADOPS Web Application Version 3.4 and prior, netCADOPS Web Application Version 7.1 and prior, netCADOPS Web Application Version 7.2x and prior, netCADOPS Web Application Version 8.0 and prior, and netCADOPS Web Application Version 8.1 and prior. A vulnerability exists in the password entry section of netCADOPS Web Application that may expose critical database information.
CVE-2018-19008 1 Abb 2 Cp400pb, Cp400pb Firmware 2019-10-09 6.8 MEDIUM 7.8 HIGH
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
CVE-2018-18997 1 Abb 4 Gate-e1, Gate-e1 Firmware, Gate-e2 and 1 more 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
Pluto Safety PLC Gateway Ethernet devices in ABB GATE-E1 and GATE-E2 all versions allows an unauthenticated attacker using the administrative web interface to insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor browser.
CVE-2018-18995 1 Abb 4 Gate-e1, Gate-e1 Firmware, Gate-e2 and 1 more 2019-10-09 7.5 HIGH 9.8 CRITICAL
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
CVE-2018-17928 1 Abb 2 Cms-770, Cms-770 Firmware 2019-10-09 3.3 LOW 6.5 MEDIUM
The product CMS-770 (Software Versions 1.7.1 and prior)is vulnerable that an attacker can read sensitive configuration files by bypassing the user authentication mechanism.
CVE-2018-17926 1 Abb 3 Eth-fw Firmware, Fw Firmware, M2m Ethernet 2019-10-09 3.3 LOW 4.3 MEDIUM
The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicious language file by bypassing the user authentication mechanism.
CVE-2018-10616 1 Abb 1 Panel Builder 800 2019-10-09 9.3 HIGH 7.8 HIGH
ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.
CVE-2017-9664 1 Abb 4 Srea-01, Srea-01 Firmware, Srea-50 and 1 more 2019-10-09 5.0 MEDIUM 9.8 CRITICAL
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refers to files using ../../ relative paths. Once the internal password file is retrieved, the password hash can be identified using a brute force attack. There is also an exploit allowing running of commands after authorization.
CVE-2017-7931 1 Abb 2 Ip Gateway, Ip Gateway Firmware 2019-10-09 7.5 HIGH 9.8 CRITICAL
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
CVE-2017-7920 1 Abb 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more 2019-10-09 5.0 MEDIUM 7.5 HIGH
An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
CVE-2017-7916 1 Abb 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more 2019-10-09 4.0 MEDIUM 6.5 MEDIUM
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
CVE-2017-7906 1 Abb 2 Ip Gateway, Ip Gateway Firmware 2019-10-09 6.8 MEDIUM 8.8 HIGH
In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.
CVE-2017-7933 1 Abb 2 Ip Gateway, Ip Gateway Firmware 2019-10-03 5.0 MEDIUM 9.8 CRITICAL
In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.
CVE-2008-2474 1 Abb 1 Pcu400 2018-10-11 10.0 HIGH N/A
Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.
CVE-2016-4511 1 Abb 1 Pcm600 2016-06-17 1.9 LOW 2.8 LOW
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file.