CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-18267 1 Ge 4 S2020, S2020 Firmware, S2020g and 1 more 2020-01-07 3.5 LOW 5.4 MEDIUM
An issue was found in GE S2020/S2020G Fast Switch 61850, S2020/S2020G Fast Switch 61850 Versions 07A03 and prior. An attacker can inject arbitrary Javascript in a specially crafted HTTP request that may be reflected back in the HTTP response. The device is also vulnerable to a stored cross-site scripting vulnerability that may allow session hijacking, disclosure of sensitive data, cross-site request forgery (CSRF) attacks, and remote code execution.
CVE-2018-8867 1 Ge 16 Pacsystems Cpu320, Pacsystems Cpu320 Firmware, Pacsystems Cru320 and 13 more 2019-10-09 7.8 HIGH 7.5 HIGH
In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow a remote attacker to send specially crafted packets causing the device to become unavailable.
CVE-2018-19003 1 Ge 6 Ex2100e, Ex2100e Firmware, Ls2100e and 3 more 2019-10-09 5.0 MEDIUM 7.5 HIGH
GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.
CVE-2018-17925 1 Ge 1 Ifix 2019-10-09 4.4 MEDIUM 4.8 MEDIUM
Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted.
CVE-2018-10615 1 Ge 1 Mds Pulsenet 2019-10-09 6.5 MEDIUM 8.1 HIGH
Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.
CVE-2018-10613 1 Ge 1 Mds Pulsenet 2019-10-09 5.0 MEDIUM 7.5 HIGH
Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
CVE-2018-10611 1 Ge 1 Mds Pulsenet 2019-10-09 7.5 HIGH 9.8 CRITICAL
Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
CVE-2017-7908 2 Ge, Gigasoft 2 Ge Communicator, Proessentials 2019-10-09 6.8 MEDIUM 7.6 HIGH
A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls.
CVE-2017-7905 1 Ge 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more 2019-10-09 5.0 MEDIUM 9.8 CRITICAL
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
CVE-2017-14008 1 Ge 1 Centricity Pacs Ra1000 2019-10-09 7.5 HIGH 9.8 CRITICAL
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
CVE-2017-14006 1 Ge 1 Xeleris 2019-10-09 7.5 HIGH 9.8 CRITICAL
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
CVE-2017-14004 1 Ge 1 Gemnet License Server 2019-10-09 7.5 HIGH 9.8 CRITICAL
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
CVE-2017-14002 1 Ge 2 Infinia Hawkeye 4, Infinia Hawkeye 4 Firmware 2019-10-09 10.0 HIGH 9.8 CRITICAL
GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
CVE-2017-12732 1 Ge 1 Intelligent Platforms Proficy Hmi\/scada Cimplicity 2019-10-09 4.9 MEDIUM 6.8 MEDIUM
A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution.
CVE-2018-15362 1 Ge 1 Cimplicity 2019-02-06 6.4 MEDIUM 9.1 CRITICAL
XXE in GE Proficy Cimplicity GDS versions 9.0 R2, 9.5, 10.0
CVE-2016-0862 1 Ge 5 Snmp\/web Adapter 1024746, Snmp\/web Adapter 1024747, Snmp\/web Adapter 1024748 and 2 more 2018-10-17 4.0 MEDIUM 6.5 MEDIUM
General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to obtain sensitive cleartext account information via unspecified vectors.
CVE-2012-0231 1 Ge 1 Intelligent Platforms Proficy Plant Applications 2018-01-11 10.0 HIGH N/A
PRLicenseMgr.exe in the Proficy Server License Manager in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12401.
CVE-2012-0230 1 Ge 1 Intelligent Platforms Proficy Plant Applications 2018-01-11 10.0 HIGH N/A
PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12299.
CVE-2012-0229 1 Ge 1 Intelligent Platforms Proficy Historian 2018-01-04 10.0 HIGH N/A
The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted session on TCP port 14000 to (1) ihDataArchiver.exe or (2) ihDataArchiver_x64.exe.
CVE-2016-0861 1 Ge 1 Ups Snmp Web Adapter Firmware 2017-09-10 9.0 HIGH 8.8 HIGH
General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors.