Filtered by vendor Rockwellautomation
Subscribe
Total
241 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-2913 | 1 Rockwellautomation | 1 Thinmanager | 2023-07-27 | N/A | 6.5 MEDIUM |
An executable used in Rockwell Automation ThinManager ThinServer can be configured to enable an API feature in the HTTPS Server Settings. This feature is disabled by default. When the API is enabled and handling requests, a path traversal vulnerability exists that allows a remote actor to leverage the privileges of the server’s file system and read arbitrary files stored in it. A malicious user could exploit this vulnerability by executing a path that contains manipulating variables. | |||||
CVE-2023-2263 | 1 Rockwellautomation | 2 Kinetix 5700, Kinetix 5700 Firmware | 2023-07-27 | N/A | 7.5 HIGH |
The Rockwell Automation Kinetix 5700 DC Bus Power Supply Series A is vulnerable to CIP fuzzing. The new ENIP connections cannot be established if impacted by this vulnerability, which prohibits operational capabilities of the device resulting in a denial-of-service attack. | |||||
CVE-2023-3595 | 1 Rockwellautomation | 24 1756-en2f Series A, 1756-en2f Series A Firmware, 1756-en2f Series B and 21 more | 2023-07-25 | N/A | 9.8 CRITICAL |
Where this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device. | |||||
CVE-2023-3596 | 1 Rockwellautomation | 6 1756-en4tr, 1756-en4tr Firmware, 1756-en4trk and 3 more | 2023-07-20 | N/A | 7.5 HIGH |
Where this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages. | |||||
CVE-2023-2072 | 1 Rockwellautomation | 2 Powermonitor 1000, Powermonitor 1000 Firmware | 2023-07-18 | N/A | 8.8 HIGH |
The Rockwell Automation PowerMonitor 1000 contains stored cross-site scripting vulnerabilities within the web page of the product. The vulnerable pages do not require privileges to access and can be injected with code by an attacker which could be used to leverage an attack on an authenticated user resulting in remote code execution and potentially the complete loss of confidentiality, integrity, and availability of the product. | |||||
CVE-2023-2746 | 1 Rockwellautomation | 1 Enhanced Him | 2023-07-18 | N/A | 9.6 CRITICAL |
The Rockwell Automation Enhanced HIM software contains an API that the application uses that is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a social engineering attack or successfully perform a Cross Site Scripting Attack (XSS). Exploitation of a CSRF could potentially lead to sensitive information disclosure and full remote access to the affected products. | |||||
CVE-2023-2637 | 1 Rockwellautomation | 2 Factorytalk Policy Manager, Factorytalk System Services | 2023-06-26 | N/A | 8.2 HIGH |
Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies. Hard-coded cryptographic key may lead to privilege escalation. This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited. | |||||
CVE-2023-2638 | 1 Rockwellautomation | 2 Factorytalk Policy Manager, Factorytalk System Services | 2023-06-26 | N/A | 5.0 MEDIUM |
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected. Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited. | |||||
CVE-2023-2639 | 1 Rockwellautomation | 2 Factorytalk Policy Manager, Factorytalk System Services | 2023-06-26 | N/A | 4.7 MEDIUM |
The underlying feedback mechanism of Rockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device. This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy. | |||||
CVE-2023-2778 | 1 Rockwellautomation | 1 Factorytalk Transaction Manager | 2023-06-26 | N/A | 7.5 HIGH |
A denial-of-service vulnerability exists in Rockwell Automation FactoryTalk Transaction Manager. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS. | |||||
CVE-2019-10952 | 1 Rockwellautomation | 8 Armor Compact Guardlogix 5370, Armor Compact Guardlogix 5370 Firmware, Compactlogix 5370 L1 and 5 more | 2023-06-20 | 7.5 HIGH | 9.8 CRITICAL |
An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier. | |||||
CVE-2019-10954 | 1 Rockwellautomation | 10 Armor Compact Guardlogix 5370, Armor Compact Guardlogix 5370 Firmware, Compact Guardlogix 5370 and 7 more | 2023-06-20 | 7.8 HIGH | 7.5 HIGH |
An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF) in CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier. | |||||
CVE-2016-2279 | 1 Rockwellautomation | 46 Compactlogix 1756-en2f Series A, Compactlogix 1756-en2f Series A Firmware, Compactlogix 1756-en2f Series B and 43 more | 2023-05-23 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in the web server in Rockwell Automation Allen-Bradley CompactLogix 1769-L* before 28.011+ allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2023-1834 | 1 Rockwellautomation | 2 Kinetix 5500, Kinetix 5500 Firmware | 2023-05-22 | N/A | 9.1 CRITICAL |
Rockwell Automation was made aware that Kinetix 5500 drives, manufactured between May 2022 and January 2023, and are running v7.13 may have the telnet and FTP ports open by default. This could potentially allow attackers unauthorized access to the device through the open ports. | |||||
CVE-2023-2443 | 1 Rockwellautomation | 1 Thinmanager | 2023-05-20 | N/A | 7.5 HIGH |
Rockwell Automation ThinManager product allows the use of medium strength ciphers. If the client requests an insecure cipher, a malicious actor could potentially decrypt traffic sent between the client and server API. | |||||
CVE-2023-2444 | 1 Rockwellautomation | 1 Factorytalk Vantagepoint | 2023-05-20 | N/A | 8.8 HIGH |
A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product. Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well. | |||||
CVE-2023-29460 | 1 Rockwellautomation | 1 Arena Simulation | 2023-05-16 | N/A | 9.8 CRITICAL |
An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow potentially resulting in a complete loss of confidentiality, integrity, and availability. | |||||
CVE-2023-29461 | 1 Rockwellautomation | 1 Arena Simulation | 2023-05-16 | N/A | 9.8 CRITICAL |
An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow in the heap. potentially resulting in a complete loss of confidentiality, integrity, and availability. | |||||
CVE-2023-29029 | 1 Rockwellautomation | 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more | 2023-05-15 | N/A | 5.9 MEDIUM |
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page. | |||||
CVE-2023-29027 | 1 Rockwellautomation | 4 Armorstart St 281e, Armorstart St 281e Firmware, Armorstart St 284ee and 1 more | 2023-05-15 | N/A | 5.9 MEDIUM |
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause interruptions to the availability of the web page. |