Total
258583 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-48737 | 2024-07-05 | N/A | N/A | ||
| Rejected reason: This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. | |||||
| CVE-2022-48736 | 2024-07-05 | N/A | N/A | ||
| Rejected reason: This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. | |||||
| CVE-2024-6488 | 2024-07-04 | N/A | N/A | ||
| Rejected reason: This is REJECTED. | |||||
| CVE-2024-6513 | 2024-07-04 | N/A | N/A | ||
| Rejected reason: CVE assigned by mistake as a duplicate. | |||||
| CVE-2024-21520 | 2024-07-04 | N/A | 6.1 MEDIUM | ||
| Versions of the package djangorestframework before 3.15.2 are vulnerable to Cross-site Scripting (XSS) via the break_long_headers template filter due to improper input sanitization before splitting and joining with <br> tags. | |||||
| CVE-2023-4088 | 1 Mitsubishielectric | 1 Gx Works3 | 2024-07-04 | N/A | 7.8 HIGH |
| Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder. | |||||
| CVE-2022-33324 | 1 Mitsubishi | 38 Melipc Mi5122-vw, Melipc Mi5122-vw Firmware, Melsec Iq-l L04 Hcpu and 35 more | 2024-07-04 | N/A | 7.5 HIGH |
| Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU Firmware versions "32" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "65" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "29" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-V Firmware versions "17" and prior, Mitsubishi Electric Corporation MELSEC iQ-L Series L04/08/16/32HCPU Firmware versions "05" and prior and Mitsubishi Electric Corporation MELIPC Series MI5122-VW Firmware versions "07" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition in Ethernet communication on the module by sending specially crafted packets. A system reset of the module is required for recovery. | |||||
| CVE-2024-34584 | 2024-07-04 | N/A | N/A | ||
| Rejected reason: ** REJECT ** DO NOT USE THIS CVE RECORD. Reason: An additional patch is required. | |||||
| CVE-2024-31486 | 2024-07-04 | N/A | 5.3 MEDIUM | ||
| A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions < V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss. | |||||
| CVE-2024-31485 | 2024-07-04 | N/A | 7.2 HIGH | ||
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. | |||||
| CVE-2024-31484 | 2024-07-04 | N/A | 7.8 HIGH | ||
| A vulnerability has been identified in CPC80 Central Processing/Communication (All versions < V16.41), CPCI85 Central Processing/Communication (All versions < V5.30), CPCX26 Central Processing/Communication (All versions < V06.02), ETA4 Ethernet Interface IEC60870-5-104 (All versions < V10.46), ETA5 Ethernet Int. 1x100TX IEC61850 Ed.2 (All versions < V03.27), PCCX26 Ax 1703 PE, Contr, Communication Element (All versions < V06.05). The affected devices contain an improper null termination vulnerability while parsing a specific HTTP header. This could allow an attacker to execute code in the context of the current process or lead to denial of service condition. | |||||
| CVE-2023-7270 | 2024-07-04 | N/A | N/A | ||
| An issue was discovered in SoftMaker Office 2024 / NX before revision 1214 and SoftMaker FreeOffice 2014 before revision 1215. FreeOffice 2021 is also affected, but won't be fixed. The SoftMaker Office and FreeOffice MSI installer files were found to produce a visible conhost.exe window running as the SYSTEM user when using the repair function of msiexec.exe. This allows a local, low-privileged attacker to use a chain of actions, to open a fully functional cmd.exe with the privileges of the SYSTEM user. | |||||
| CVE-2023-33919 | 1 Siemens | 3 Cp-8031 Master Module, Cp-8050 Master Module, Cpci85 Firmware | 2024-07-04 | N/A | 7.2 HIGH |
| A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. | |||||
| CVE-2024-27867 | 2024-07-04 | N/A | N/A | ||
| An authentication issue was addressed with improved state management. This issue is fixed in AirPods Firmware Update 6A326, AirPods Firmware Update 6F8, and Beats Firmware Update 6F8. When your headphones are seeking a connection request to one of your previously paired devices, an attacker in Bluetooth range might be able to spoof the intended source device and gain access to your headphones. | |||||
| CVE-2024-27180 | 2024-07-04 | N/A | 6.7 MEDIUM | ||
| An attacker with admin access can install rogue applications. As for the affected products/models/versions, see the reference URL. | |||||
| CVE-2024-27179 | 2024-07-04 | N/A | 4.7 MEDIUM | ||
| Admin cookies are written in clear-text in logs. An attacker can retrieve them and bypass the authentication mechanism. As for the affected products/models/versions, see the reference URL. | |||||
| CVE-2024-27178 | 2024-07-04 | N/A | 7.2 HIGH | ||
| An attacker can get Remote Code Execution by overwriting files. Overwriting files is enable by falsifying file name variable. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL. | |||||
| CVE-2024-27177 | 2024-07-04 | N/A | 7.2 HIGH | ||
| An attacker can get Remote Code Execution by overwriting files. Overwriting files is enable by falsifying package name variable. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL. | |||||
| CVE-2024-27176 | 2024-07-04 | N/A | 7.2 HIGH | ||
| An attacker can get Remote Code Execution by overwriting files. Overwriting files is enable by falsifying session ID variable. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL. | |||||
| CVE-2024-27175 | 2024-07-04 | N/A | 4.4 MEDIUM | ||
| Remote Command program allows an attacker to read any file using a Local File Inclusion vulnerability. An attacker can read any file on the printer. As for the affected products/models/versions, see the reference URL. | |||||