Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1761 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-27411 1 Siemens 1 Ruggedcom Crossbow 2023-08-10 N/A 8.8 HIGH
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges.
CVE-2023-37372 1 Siemens 1 Ruggedcom Crossbow 2023-08-10 N/A 9.8 CRITICAL
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an unauthenticated remote attackers to execute arbitrary SQL queries on the server database.
CVE-2023-39184 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-39183 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-39182 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-39181 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process.
CVE-2023-39187 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-39186 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-39185 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-39188 1 Siemens 1 Solid Edge 2023-08-10 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.
CVE-2021-23362 2 Npmjs, Siemens 2 Hosted-git-info, Sinec Infrastructure Network Services 2023-08-08 5.0 MEDIUM 5.3 MEDIUM
The package hosted-git-info before 3.0.8 are vulnerable to Regular Expression Denial of Service (ReDoS) via regular expression shortcutMatch in the fromUrl function in index.js. The affected regular expression exhibits polynomial worst-case time complexity.
CVE-2022-37893 2 Arubanetworks, Siemens 4 Arubaos, Instant, Scalance W1750d and 1 more 2023-08-08 N/A 7.8 HIGH
An authenticated command injection vulnerability exists in the Aruba InstantOS and ArubaOS 10 command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InstantOS that address this security vulnerability.
CVE-2023-30986 1 Siemens 1 Solid Edge Se2023 2023-08-08 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561)
CVE-2023-30985 1 Siemens 1 Solid Edge Se2023 2023-08-08 N/A 5.5 MEDIUM
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted OBJ file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19426)
CVE-2022-45937 1 Siemens 18 Pxc00-e96.a, Pxc00-e96.a Firmware, Pxc100-e96.a and 15 more 2023-08-08 N/A 6.5 MEDIUM
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials.
CVE-2021-25677 1 Siemens 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more 2023-08-08 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.
CVE-2020-28388 4 Arm, Mips, Powerpc Project and 1 more 8 Arm, Mips, Powerpc and 5 more 2023-08-08 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones.
CVE-2020-27738 1 Siemens 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more 2023-08-08 5.8 MEDIUM 7.4 HIGH
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.
CVE-2020-27737 1 Siemens 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more 2023-08-08 5.8 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.
CVE-2020-27736 1 Siemens 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more 2023-08-08 5.8 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.