Filtered by vendor Schneider-electric
Subscribe
Total
746 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-22808 | 1 Schneider-electric | 1 Guicon | 2022-02-02 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior | |||||
CVE-2021-22807 | 1 Schneider-electric | 1 Guicon | 2022-02-02 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior | |||||
CVE-2017-6026 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2022-02-02 | 6.4 MEDIUM | 9.1 CRITICAL |
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised. | |||||
CVE-2017-7689 | 1 Schneider-electric | 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware | 2022-02-02 | 10.0 HIGH | 9.8 CRITICAL |
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0. | |||||
CVE-2018-7229 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials. | |||||
CVE-2018-7230 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 6.8 MEDIUM | 8.8 HIGH |
A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67. | |||||
CVE-2018-7231 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'. | |||||
CVE-2018-7232 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'. | |||||
CVE-2018-7233 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'. | |||||
CVE-2018-7234 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.8 HIGH | 7.5 HIGH |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate. | |||||
CVE-2018-7235 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.8 HIGH | 7.5 HIGH |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file' | |||||
CVE-2018-7228 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges. | |||||
CVE-2018-7227 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker. | |||||
CVE-2018-7236 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 5.8 MEDIUM | 8.1 HIGH |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service. | |||||
CVE-2018-7237 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 6.4 MEDIUM | 9.1 CRITICAL |
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file' | |||||
CVE-2018-7238 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.5 HIGH | 9.8 CRITICAL |
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code. | |||||
CVE-2015-0982 | 1 Schneider-electric | 1 Pelco Ds-nv | 2022-02-02 | 7.5 HIGH | N/A |
Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors. | |||||
CVE-2015-3962 | 1 Schneider-electric | 1 Struxureware Building Expert Multi-purpose Management | 2022-02-02 | 5.0 MEDIUM | N/A |
Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network. | |||||
CVE-2016-8374 | 1 Schneider-electric | 16 Magelis Gto Advanced Optimum Panel, Magelis Gto Advanced Optimum Panel Firmware, Magelis Gtu Universal Panel and 13 more | 2022-02-02 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION. | |||||
CVE-2016-8367 | 1 Schneider-electric | 16 Magelis Gto Advanced Optimum Panel, Magelis Gto Advanced Optimum Panel Firmware, Magelis Gtu Universal Panel and 13 more | 2022-02-02 | 5.0 MEDIUM | 5.3 MEDIUM |
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker can open multiple connections to a targeted web server and keep connections open preventing new connections from being made, rendering the web server unavailable during an attack. |