Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 746 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-40891 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
CVE-2023-40800 1 Tenda 2 Ac23, Ac23 Firmware 2023-08-29 N/A 8.8 HIGH
The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn.
CVE-2023-40801 1 Tenda 2 Ac23, Ac23 Firmware 2023-08-29 N/A 8.8 HIGH
The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-40802 1 Tenda 2 Ac23, Ac23 Firmware 2023-08-29 N/A 6.5 MEDIUM
The get_parentControl_list_Info function does not verify the parameters entered by the user, causing a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-40915 1 Tenda 2 Ax3, Ax3 Firmware 2023-08-29 N/A 7.5 HIGH
Tenda AX3 v16.03.12.11 has a stack buffer overflow vulnerability detected at function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter.
CVE-2023-40797 1 Tenda 2 Ac23, Ac23 Firmware 2023-08-29 N/A 8.8 HIGH
In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability.
CVE-2023-40798 1 Tenda 2 Ac23, Ac23 Firmware 2023-08-29 N/A 8.8 HIGH
In Tenda AC23 v16.03.07.45_cn, the formSetIPv6status and formGetWanParameter functions do not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability.
CVE-2023-40799 1 Tenda 2 Ac23, Ac23 Firmware 2023-08-29 N/A 9.8 CRITICAL
Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function.
CVE-2023-39786 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-24 N/A 7.5 HIGH
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.
CVE-2023-39785 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-24 N/A 7.5 HIGH
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function.
CVE-2023-39784 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2023-08-24 N/A 7.5 HIGH
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function.
CVE-2023-39673 1 Tenda 2 Ac15, Ac15 Firmware 2023-08-23 N/A 9.8 CRITICAL
Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().
CVE-2023-39670 1 Tenda 2 Ac6, Ac6 Firmware 2023-08-23 N/A 9.8 CRITICAL
Tenda AC6 _US_AC6V1.0BR_V15.03.05.16 was discovered to contain a buffer overflow via the function fgets.
CVE-2023-39672 1 Tenda 2 Wh450a, Wh450a Firmware 2023-08-23 N/A 9.8 CRITICAL
Tenda WH450 v1.0.0.18 was discovered to contain a buffer overflow via the function fgets.
CVE-2023-39829 1 Tenda 2 A18, A18 Firmware 2023-08-18 N/A 7.5 HIGH
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
CVE-2023-39828 1 Tenda 2 A18, A18 Firmware 2023-08-18 N/A 7.5 HIGH
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
CVE-2023-39827 1 Tenda 2 A18, A18 Firmware 2023-08-18 N/A 7.5 HIGH
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
CVE-2023-38937 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
CVE-2023-38936 1 Tenda 18 Ac10, Ac10 Firmware, Ac1206 and 15 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-38935 1 Tenda 10 Ac10, Ac10 Firmware, Ac1206 and 7 more 2023-08-10 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.