Total
10481 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-26073 | 1 Samsung | 18 Exynos 1080, Exynos 1080 Firmware, Exynos 1280 and 15 more | 2023-03-17 | N/A | 9.8 CRITICAL |
An issue was discovered in Samsung Mobile Chipset and Baseband Modem Chipset for Exynos 850, Exynos 980, Exynos 1080, Exynos 1280, Exynos 2200, Exynos Modem 5123, Exynos Modem 5300, and Exynos Auto T5123. A heap-based buffer overflow in the 5G MM message codec can occur due to insufficient parameter validation when decoding the extended emergency number list. | |||||
CVE-2023-26072 | 1 Samsung | 18 Exynos 1080, Exynos 1080 Firmware, Exynos 1280 and 15 more | 2023-03-17 | N/A | 9.8 CRITICAL |
An issue was discovered in Samsung Mobile Chipset and Baseband Modem Chipset for Exynos 850, Exynos 980, Exynos 1080, Exynos 1280, Exynos 2200, Exynos Modem 5123, Exynos Modem 5300, and Exynos Auto T5123. A heap-based buffer overflow in the 5G MM message codec can occur due to insufficient parameter validation when decoding the Emergency number list. | |||||
CVE-2022-32863 | 1 Apple | 2 Macos, Safari | 2023-03-17 | N/A | 9.8 CRITICAL |
A memory corruption issue was addressed with improved state management. This issue is fixed in Safari 15.6, macOS Monterey 12.5. Processing maliciously crafted web content may lead to arbitrary code execution. | |||||
CVE-2023-27398 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2023-03-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20304) | |||||
CVE-2023-27399 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2023-03-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20299, ZDI-CAN-20346) | |||||
CVE-2023-27400 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2023-03-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20300) | |||||
CVE-2023-27404 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2023-03-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20433) | |||||
CVE-2023-27406 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2023-03-16 | N/A | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20449) | |||||
CVE-2023-25283 | 1 Dlink | 2 Dir-820l, Dir-820l Firmware | 2023-03-16 | N/A | 7.5 HIGH |
A stack overflow vulnerability in D-Link DIR820LA1_FW106B02 allows attackers to cause a denial of service via the reserveDHCP_HostName_1.1.1.0 parameter to lan.asp. | |||||
CVE-2022-47457 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-03-16 | N/A | 5.5 MEDIUM |
In wlan driver, there is a possible missing params check. This could lead to local denial of service in wlan services. | |||||
CVE-2022-47459 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-03-16 | N/A | 5.5 MEDIUM |
In wlan driver, there is a possible missing params check. This could lead to local denial of service in wlan services. | |||||
CVE-2023-27117 | 1 Webassembly | 1 Webassembly | 2023-03-15 | N/A | 7.8 HIGH |
WebAssembly v1.0.29 was discovered to contain a heap overflow via the component component wabt::Node::operator. | |||||
CVE-2023-24566 | 1 Siemens | 1 Solid Edge Se2023 | 2023-03-14 | N/A | 3.3 LOW |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472) | |||||
CVE-2023-24560 | 1 Siemens | 1 Solid Edge Se2023 | 2023-03-14 | N/A | 7.8 HIGH |
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process. | |||||
CVE-2022-46348 | 1 Siemens | 1 Parasolid | 2023-03-14 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383) | |||||
CVE-2022-46347 | 1 Siemens | 1 Parasolid | 2023-03-14 | N/A | 7.8 HIGH |
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079) | |||||
CVE-2022-34819 | 1 Siemens | 30 Simatic Cp 1242-7 V2, Simatic Cp 1242-7 V2 Firmware, Simatic Cp 1243-1 and 27 more | 2023-03-14 | 9.3 HIGH | 10.0 CRITICAL |
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device. | |||||
CVE-2021-31887 | 1 Siemens | 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more | 2023-03-13 | 6.5 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016) | |||||
CVE-2023-20630 | 2 Google, Mediatek | 25 Android, Mt6580, Mt6735 and 22 more | 2023-03-13 | N/A | 6.7 MEDIUM |
In usb, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS07628505; Issue ID: ALPS07628505. | |||||
CVE-2023-20632 | 2 Google, Mediatek | 25 Android, Mt6580, Mt6735 and 22 more | 2023-03-13 | N/A | 6.7 MEDIUM |
In usb, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS07628506; Issue ID: ALPS07628506. |