Total
77 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-10927 | 1 Siemens | 10 Scalance Xb-200, Scalance Xb-200 Firmware, Scalance Xc-200 and 7 more | 2021-10-28 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device. | |||||
CVE-2021-0286 | 1 Juniper | 1 Junos Os Evolved | 2021-10-25 | 7.8 HIGH | 7.5 HIGH |
A vulnerability in the handling of exceptional conditions in Juniper Networks Junos OS Evolved (EVO) allows an attacker to send specially crafted packets to the device, causing the Advanced Forwarding Toolkit manager (evo-aftmand-bt or evo-aftmand-zx) process to crash and restart, impacting all traffic going through the FPC, resulting in a Denial of Service (DoS). Continued receipt and processing of these packets will create a sustained Denial of Service (DoS) condition. Following messages will be logged prior to the crash: Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:32710470974358 label:1089551617 for session:18 probe:35 Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:19241453497049 label:1089551617 for session:18 probe:37 Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:19241453497049 label:1089551617 for session:18 probe:44 Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:32710470974358 label:1089551617 for session:18 probe:47 Feb 2 10:14:39 fpc0 audit[16263]: ANOM_ABEND auid=4294967295 uid=0 gid=0 ses=4294967295 pid=16263 comm="EvoAftManBt-mai" exe="/usr/sbin/evo-aftmand-bt" sig=11 Feb 2 10:14:39 fpc0 kernel: audit: type=1701 audit(1612260879.272:17): auid=4294967295 uid=0 gid=0 ses=4294967295 pid=16263 comm="EvoAftManBt-mai" exe="/usr/sbin/evo-aftmand-bt" sig=1 This issue affects Juniper Networks Junos OS Evolved: All versions prior to 20.4R2-EVO; 21.1 versions prior to 21.1R2-EVO. | |||||
CVE-2021-0241 | 1 Juniper | 1 Junos | 2021-07-23 | 3.3 LOW | 6.5 MEDIUM |
On Juniper Networks Junos OS platforms configured as DHCPv6 local server or DHCPv6 Relay Agent, Juniper Networks Dynamic Host Configuration Protocol Daemon (JDHCPD) process might crash with a core dump if a specific DHCPv6 packet is received, resulting in a restart of the daemon. The daemon automatically restarts without intervention, but continued receipt and processing of these specific packets will repeatedly crash the JDHCPD process and sustain the Denial of Service (DoS) condition. This issue only affects DHCPv6. DHCPv4 is not affected by this issue. This issue affects: Juniper Networks Junos OS 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R3-S7; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R3-S1; 19.3 versions prior to 19.3R3-S1, 19.3R3-S2; 19.4 versions prior to 19.4R3-S1; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S2, 20.3R2. | |||||
CVE-2021-0240 | 1 Juniper | 1 Junos | 2021-07-23 | 2.9 LOW | 6.5 MEDIUM |
On Juniper Networks Junos OS platforms configured as DHCPv6 local server or DHCPv6 Relay Agent, the Juniper Networks Dynamic Host Configuration Protocol Daemon (JDHCPD) process might crash if a malformed DHCPv6 packet is received, resulting in a restart of the daemon. The daemon automatically restarts without intervention, but continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects DHCPv6. DHCPv4 is not affected by this issue. This issue affects Juniper Networks Junos OS: 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R3-S7; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2. | |||||
CVE-2021-25419 | 1 Samsung | 1 Internet | 2021-06-21 | 4.3 MEDIUM | 6.5 MEDIUM |
Non-compliance of recommended secure coding scheme in Samsung Internet prior to version 14.0.1.62 allows attackers to display fake URL in address bar via phising URL link. | |||||
CVE-2021-25425 | 1 Samsung | 1 Health | 2021-06-16 | 5.0 MEDIUM | 5.3 MEDIUM |
Improper check vulnerability in Samsung Health prior to version 6.17 allows attacker to read internal cache data via exported component. | |||||
CVE-2021-0264 | 1 Juniper | 21 Junos, Junos Os Evolved, Mx10 and 18 more | 2021-04-30 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bulletin TSB17931 (login required). This issue affects: Juniper Networks Junos OS on MX Series: 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2. Juniper Networks Junos OS Evolved on PTX10003, PTX10008: All versions prior to 20.4R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 19.3R1. | |||||
CVE-2021-25335 | 2 Google, Samsung | 2 Android, One Ui | 2021-03-11 | 1.9 LOW | 2.5 LOW |
Improper lockscreen status check in cocktailbar service in Samsung mobile devices prior to SMR Mar-2021 Release 1 allows unauthenticated users to access hidden notification contents over the lockscreen in specific condition. | |||||
CVE-2021-25348 | 1 Samsung | 1 Internet | 2021-03-05 | 2.1 LOW | 2.4 LOW |
Improper permission grant check in Samsung Internet prior to version 13.0.1.60 allows access to files in internal storage without authorized STORAGE permission. | |||||
CVE-2021-0221 | 1 Juniper | 1 Junos | 2021-02-05 | 2.9 LOW | 6.5 MEDIUM |
In an EVPN/VXLAN scenario, if an IRB interface with a virtual gateway address (VGA) is configured on a PE, a traffic loop may occur upon receipt of specific IP multicast traffic. The traffic loop will cause interface traffic to increase abnormally, ultimately leading to a Denial of Service (DoS) in packet processing. The following command could be used to monitor the interface traffic: user@junos> monitor interface traffic Interface Link Input packets (pps) Output packets (pps) et-0/0/1 Up 6492089274364 (70994959) 6492089235319 (70994956) et-0/0/25 Up 343458103 (1) 156844 (0) ae0 Up 9132519197257 (70994959) 9132519139454 (70994956) This issue affects Juniper Networks Junos OS on QFX Series: all versions prior to 17.3R3-S10; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S6; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S5, 18.4R3-S5; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3-S3; 19.2 versions prior to 19.2R1-S5, 19.2R3-S1; 19.3 versions prior to 19.3R2-S5, 19.3R3; 19.4 versions prior to 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R1-S2, 20.2R2. | |||||
CVE-2019-10928 | 1 Siemens | 2 Scalance Sc-600, Scalance Sc-600 Firmware | 2020-10-02 | 4.6 MEDIUM | 6.6 MEDIUM |
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device. | |||||
CVE-2020-2075 | 1 Sick | 60 Clv620, Clv620 Firmware, Clv621 and 57 more | 2020-09-04 | 5.0 MEDIUM | 7.5 HIGH |
Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x – CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH. | |||||
CVE-2020-1644 | 1 Juniper | 2 Junos, Junos Os Evolved | 2020-07-24 | 5.0 MEDIUM | 7.5 HIGH |
On Juniper Networks Junos OS and Junos OS Evolved devices, the receipt of a specific BGP UPDATE packet causes an internal counter to be incremented incorrectly, which over time can lead to the routing protocols process (RPD) crash and restart. This issue affects both IBGP and EBGP multihop deployment in IPv4 or IPv6 network. This issue affects: Juniper Networks Junos OS: 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S4; 18.2X75 versions prior to 18.2X75-D13, 18.2X75-D411.1, 18.2X75-D420.18, 18.2X75-D52.3, 18.2X75-D60; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S2, 19.4R2. Juniper Networks Junos OS Evolved: any releases prior to 20.1R2-EVO. This issue does not affect Juniper Networks Junos OS releases prior to 17.3R1. | |||||
CVE-2018-5463 | 1 Lcds | 1 Laquis Scada | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution. | |||||
CVE-2018-12551 | 1 Eclipse | 1 Mosquitto | 2019-10-09 | 6.8 MEDIUM | 8.1 HIGH |
When Eclipse Mosquitto version 1.0 to 1.5.5 (inclusive) is configured to use a password file for authentication, any malformed data in the password file will be treated as valid. This typically means that the malformed data becomes a username and no password. If this occurs, clients can circumvent authentication and get access to the broker by using the malformed username. In particular, a blank line will be treated as a valid empty username. Other security measures are unaffected. Users who have only used the mosquitto_passwd utility to create and modify their password files are unaffected by this vulnerability. | |||||
CVE-2017-16014 | 1 Http-proxy Project | 1 Http-proxy | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
Http-proxy is a proxying library. Because of the way errors are handled in versions before 0.7.0, an attacker that forces an error can crash the server, causing a denial of service. | |||||
CVE-2019-11245 | 1 Kubernetes | 1 Kubernetes | 2019-09-19 | 4.6 MEDIUM | 7.8 HIGH |
In kubelet v1.13.6 and v1.14.2, containers for pods that do not specify an explicit runAsUser attempt to run as uid 0 (root) on container restart, or if the image was previously pulled to the node. If the pod specified mustRunAsNonRoot: true, the kubelet will refuse to start the container as root. If the pod did not specify mustRunAsNonRoot: true, the kubelet will run the container as uid 0. |