Vulnerabilities (CVE)

Filtered by CWE-345
Total 380 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-28370 1 Verizon 2 Lvskihp Outdoorunit, Lvskihp Outdoorunit Firmware 2023-08-08 N/A 7.5 HIGH
On Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 devices, the RPC endpoint crtc_fw_upgrade provides a means of provisioning a firmware update for the device. /lib/functions/wnc_jsonsh/wnc_crtc_fw.sh has no cryptographic validation of the image, thus allowing an attacker to modify the installed firmware.
CVE-2021-44850 1 Amd 20 Xilinx Z-7007s, Xilinx Z-7007s Firmware, Xilinx Z-7010 and 17 more 2023-08-08 4.6 MEDIUM 6.8 MEDIUM
On Xilinx Zynq-7000 SoC devices, physical modification of an SD boot image allows for a buffer overflow attack in the ROM. Because the Zynq-7000's boot image header is unencrypted and unauthenticated before use, an attacker can modify the boot header stored on an SD card so that a secure image appears to be unencrypted, and they will be able to modify the full range of register initialization values. Normally, these registers will be restricted when booting securely. Of importance to this attack are two registers that control the SD card's transfer type and transfer size. These registers could be modified a way that causes a buffer overflow in the ROM.
CVE-2022-26871 1 Trendmicro 2 Apex Central, Apex One 2023-08-08 7.5 HIGH 9.8 CRITICAL
An arbitrary file upload vulnerability in Trend Micro Apex Central could allow an unauthenticated remote attacker to upload an arbitrary file which could lead to remote code execution.
CVE-2021-45419 1 Starcharge 4 Nova 360 Cabinet, Nova 360 Cabinet Firmware, Titan 180 Premium and 1 more 2023-08-08 6.5 MEDIUM 8.8 HIGH
Certain Starcharge products are affected by Improper Input Validation. The affected products include: Nova 360 Cabinet <= 1.3.0.0.7b102 - Fixed: Beta1.3.0.1.0 and Titan 180 Premium <= 1.3.0.0.6 - Fixed: 1.3.0.0.9.
CVE-2022-20396 1 Google 1 Android 2023-08-08 N/A 5.5 MEDIUM
In SettingsActivity.java, there is a possible way to make a device discoverable over Bluetooth, without permission or user interaction, due to a permissions bypass. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-12L Android-13Android ID: A-234440688
CVE-2022-30315 1 Honeywell 2 Safety Manager, Safety Manager Firmware 2023-08-08 N/A 9.8 CRITICAL
Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
CVE-2022-25262 1 Jetbrains 1 Hub 2023-08-08 7.5 HIGH 9.8 CRITICAL
In JetBrains Hub before 2022.1.14434, SAML request takeover was possible.
CVE-2022-36360 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2023-07-21 N/A 7.5 HIGH
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker to manipulate a firmware update and flash it to the device.
CVE-2022-0715 1 Schneider-electric 66 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 63 more 2023-07-21 6.4 MEDIUM 9.1 CRITICAL
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2023-37264 1 Linuxfoundation 1 Tekton Pipelines 2023-07-18 N/A 4.3 MEDIUM
Tekton Pipelines project provides k8s-style resources for declaring CI/CD-style pipelines. Starting in version 0.35.0, pipelines do not validate child UIDs, which means that a user that has access to create TaskRuns can create their own Tasks that the Pipelines controller will accept as the child Task. While the software stores and validates the PipelineRun's (api version, kind, name, uid) in the child Run's OwnerReference, it only store (api version, kind, name) in the ChildStatusReference. This means that if a client had access to create TaskRuns on a cluster, they could create a child TaskRun for a pipeline with the same name + owner reference, and the Pipeline controller picks it up as if it was the original TaskRun. This is problematic since it can let users modify the config of Pipelines at runtime, which violates SLSA L2 Service Generated / Non-falsifiable requirements. This issue can be used to trick the Pipeline controller into associating unrelated Runs to the Pipeline, feeding its data through the rest of the Pipeline. This requires access to create TaskRuns, so impact may vary depending on one Tekton setup. If users already have unrestricted access to create any Task/PipelineRun, this does not grant any additional capabilities. As of time of publication, there are no known patches for this issue.
CVE-2023-30759 1 Ricoh 1 Printer Driver Packager Nx 2023-06-27 N/A 7.8 HIGH
The driver installation package created by Printer Driver Packager NX v1.0.02 to v1.1.25 fails to detect its modification and may spawn an unexpected process with the administrative privilege. If a non-administrative user modifies the driver installation package and runs it on the target PC, an arbitrary program may be executed with the administrative privilege.
CVE-2023-34113 1 Zoom 1 Zoom 2023-06-21 N/A 8.8 HIGH
Insufficient verification of data authenticity in Zoom for Windows clients before 5.14.0 may allow an authenticated user to potentially enable an escalation of privilege via network access.
CVE-2023-2866 1 Advantech 1 Webaccess 2023-06-15 N/A 7.8 HIGH
If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server.
CVE-2023-28386 2 Control4, Snapone 13 Ca-1, Ca-10, Ea-1 and 10 more 2023-05-27 N/A 9.8 CRITICAL
Snap One OvrC Pro devices versions 7.2 and prior do not validate firmware updates correctly. The device only calculates the MD5 hash of the firmware and does not check using a private-public key mechanism. The lack of complete PKI system firmware signature could allow attackers to upload arbitrary firmware updates, resulting in code execution.
CVE-2023-32993 1 Jenkins 1 Saml Single Sign On 2023-05-26 N/A 4.8 MEDIUM
Jenkins SAML Single Sign On(SSO) Plugin 2.0.2 and earlier does not perform hostname validation when connecting to miniOrange or the configured IdP to retrieve SAML metadata, which could be abused using a man-in-the-middle attack to intercept these connections.
CVE-2023-27979 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2023-05-24 N/A 6.5 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2020-7982 1 Openwrt 2 Lede, Openwrt 2023-05-24 6.8 MEDIUM 8.1 HIGH
An issue was discovered in OpenWrt 18.06.0 to 18.06.6 and 19.07.0, and LEDE 17.01.0 to 17.01.7. A bug in the fork of the opkg package manager before 2020-01-25 prevents correct parsing of embedded checksums in the signed repository index, allowing a man-in-the-middle attacker to inject arbitrary package payloads (which are installed without verification).
CVE-2023-31502 1 Apsystems 3 Alternergy Power Control Software, Ecu-c, Ecu-r 2023-05-22 N/A 7.2 HIGH
Altenergy Power Control Software C1.2.5 was discovered to contain a remote code execution (RCE) vulnerability via the component /models/management_model.php.
CVE-2023-27977 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2023-05-15 N/A 5.3 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2022-44420 2 Google, Unisoc 14 Android, S8000, Sc7731e and 11 more 2023-05-12 N/A 5.5 MEDIUM
In modem, there is a possible missing verification of HashMME value in Security Mode Command. This could local denial of service with no additional execution privileges.