Vulnerabilities (CVE)

Filtered by CWE-345
Total 380 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-41203 1 Google 1 Tensorflow 2022-10-20 4.6 MEDIUM 7.8 HIGH
TensorFlow is an open source platform for machine learning. In affected versions an attacker can trigger undefined behavior, integer overflows, segfaults and `CHECK`-fail crashes if they can change saved checkpoints from outside of TensorFlow. This is because the checkpoints loading infrastructure is missing validation for invalid file formats. The fixes will be included in TensorFlow 2.7.0. We will also cherrypick these commits on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range.
CVE-2021-20267 2 Openstack, Redhat 2 Neutron, Openstack Platform 2022-10-07 5.5 MEDIUM 7.1 HIGH
A flaw was found in openstack-neutron's default Open vSwitch firewall rules. By sending carefully crafted packets, anyone in control of a server instance connected to the virtual switch can impersonate the IPv6 addresses of other systems on the network, resulting in denial of service or in some cases possibly interception of traffic intended for other destinations. Only deployments using the Open vSwitch driver are affected. Source: OpenStack project. Versions before openstack-neutron 15.3.3, openstack-neutron 16.3.1 and openstack-neutron 17.1.1 are affected.
CVE-2022-2255 2 Debian, Modwsgi 2 Debian Linux, Mod Wsgi 2022-10-01 N/A 7.5 HIGH
A vulnerability was found in mod_wsgi. The X-Client-IP header is not removed from a request from an untrusted proxy, allowing an attacker to pass the X-Client-IP header to the target WSGI application because the condition to remove it is missing.
CVE-2022-36130 1 Hashicorp 1 Boundary 2022-09-09 N/A 9.9 CRITICAL
HashiCorp Boundary up to 0.10.1 did not properly perform data integrity checks to ensure the resources were associated with the correct scopes, allowing potential privilege escalation for authorized users of another scope. Fixed in Boundary 0.10.2.
CVE-2021-4122 1 Cryptsetup Project 1 Cryptsetup 2022-08-29 N/A 4.3 MEDIUM
It was found that a specially crafted LUKS header could trick cryptsetup into disabling encryption during the recovery of the device. An attacker with physical access to the medium, such as a flash disk, could use this flaw to force a user into permanently disabling the encryption layer of that medium.
CVE-2022-2793 1 Emerson 1 Electric\'s Proficy 2022-08-24 N/A 7.8 HIGH
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-353 Missing Support for Integrity Check, and has no authentication or authorization of data packets after establishing a connection for the SRTP protocol.
CVE-2022-2789 1 Emerson 1 Electric\'s Proficy 2022-08-23 N/A 5.5 MEDIUM
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-345 Insufficient Verification of Data Authenticity, and can display logic that is different than the compiled logic.
CVE-2022-28757 1 Zoom 1 Meetings 2022-08-23 N/A 7.8 HIGH
The Zoom Client for Meetings for macOS (Standard and for IT Admin) starting with version 5.7.3 and before 5.11.6 contains a vulnerability in the auto update process. A local low-privileged user could exploit this vulnerability to escalate their privileges to root.
CVE-2022-30262 1 Emerson 4 Controlwave Micro, Controlwave Micro Firmware, Controlwave Pac and 1 more 2022-08-20 N/A 7.8 HIGH
The Emerson ControlWave 'Next Generation' RTUs through 2022-05-02 mishandle firmware integrity. They utilize the BSAP-IP protocol to transmit firmware updates. Firmware updates are supplied as CAB archive files containing a binary firmware image. In all cases, firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks.
CVE-2022-30264 1 Emerson 10 Dl8000, Dl8000 Firmware, Fb3000 Rtu and 7 more 2022-08-17 N/A 9.8 CRITICAL
The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations.
CVE-2020-1755 1 Moodle 1 Moodle 2022-08-17 N/A 5.3 MEDIUM
In Moodle before 3.8.2, 3.7.5, 3.6.9 and 3.5.11, X-Forwarded-For headers could be used to spoof a user's IP, in order to bypass remote address checks.
CVE-2022-37008 1 Huawei 3 Emui, Harmonyos, Magic Ui 2022-08-15 N/A 7.5 HIGH
The recovery module has a vulnerability of bypassing the verification of an update package before use. Successful exploitation of this vulnerability may affect system stability.
CVE-2019-10943 1 Siemens 22 Simatic Et 200sp Open Controller Cpu 1515sp Pc, Simatic Et 200sp Open Controller Cpu 1515sp Pc2, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware and 19 more 2022-08-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
CVE-2022-29958 1 Jtekt 34 Nano 10gx Tuc-1157, Nano 10gx Tuc-1157 Firmware, Nano Cpu Tuc-6941 and 31 more 2022-08-03 N/A 9.8 CRITICAL
JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory address and a blob of machine code. The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to execute arbitrary machine code on the PLC's CPU module in the context of the runtime. In the case of the PC10G-CPU, and likely for other CPU modules of the TOYOPUC family, a processor without MPU or MMU is used and this no memory protection or privilege-separation capabilities are available, giving an attacker full control over the CPU.
CVE-2021-29462 1 Pupnp Project 1 Pupnp 2022-08-03 7.5 HIGH 9.8 CRITICAL
The Portable SDK for UPnP Devices is an SDK for development of UPnP device and control point applications. The server part of pupnp (libupnp) appears to be vulnerable to DNS rebinding attacks because it does not check the value of the `Host` header. This can be mitigated by using DNS revolvers which block DNS-rebinding attacks. The vulnerability is fixed in version 1.14.6 and later.
CVE-2022-30269 1 Motorola 2 Ace1000, Ace1000 Firmware 2022-08-02 N/A 8.8 HIGH
Motorola ACE1000 RTUs through 2022-05-02 mishandle application integrity. They allow for custom application installation via either STS software, the C toolkit, or the ACE1000 Easy Configurator. In the case of the Easy Configurator, application images (as PLX/DAT/APP/CRC files) are uploaded via the Web UI. In case of the C toolkit, they are transferred and installed using SFTP/SSH. In each case, application images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks.
CVE-2021-26608 2 Handysoft, Microsoft 2 Hshell, Windows 2022-08-02 7.5 HIGH 9.8 CRITICAL
An arbitrary file download and execution vulnerability was found in the HShell.dll of handysoft Co., Ltd groupware ActiveX module. This issue is due to missing support for integrity check of download URL or downloaded file hash.
CVE-2022-34763 1 Schneider-electric 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more 2022-07-27 N/A 7.5 HIGH
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
CVE-2022-31598 1 Sap 1 Business Objects Business Intelligence Platform 2022-07-16 4.9 MEDIUM 5.4 MEDIUM
Due to insufficient input validation, SAP Business Objects - version 420, allows an authenticated attacker to submit a malicious request through an allowed operation. On successful exploitation, an attacker can view or modify information causing a limited impact on confidentiality and integrity of the application.
CVE-2015-5236 1 Icedtea-web Project 1 Icedtea-web 2022-07-15 5.0 MEDIUM 7.5 HIGH
It was discovered that the IcedTea-Web used codebase attribute of the <applet> tag on the HTML page that hosts Java applet in the Same Origin Policy (SOP) checks. As the specified codebase does not have to match the applet's actual origin, this allowed malicious site to bypass SOP via spoofed codebase value.