CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-34113 1 Adobe 1 Coldfusion 2024-07-19 N/A 5.5 MEDIUM
ColdFusion versions 2023u7, 2021u13 and earlier are affected by a Weak Cryptography for Passwords vulnerability that could result in a security feature bypass. This vulnerability arises due to the use of insufficiently strong cryptographic algorithms or flawed implementation that compromises the confidentiality of password data. An attacker could exploit this weakness to decrypt or guess passwords, potentially gaining unauthorized access to protected resources. Exploitation of this issue does not require user interaction.
CVE-2024-36823 1 Ninjaframework 1 Ninja 2024-07-17 N/A 7.5 HIGH
The encrypt() function of Ninja Core v7.0.0 was discovered to use a weak cryptographic algorithm, leading to a possible leakage of sensitive information.
CVE-2024-38867 2024-07-09 N/A 5.9 MEDIUM
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS). This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over to and from those ports.
CVE-2017-11317 1 Telerik 1 Ui For Asp.net Ajax 2024-07-03 7.5 HIGH 9.8 CRITICAL
Telerik.Web.UI in Progress Telerik UI for ASP.NET AJAX before R1 2017 and R2 before R2 2017 SP2 uses weak RadAsyncUpload encryption, which allows remote attackers to perform arbitrary file uploads or execute arbitrary code.
CVE-2024-30119 2024-07-03 N/A 3.7 LOW
HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header.  This could allow an attacker to intercept or manipulate data during redirection.
CVE-2024-23580 2024-07-03 N/A 6.5 MEDIUM
HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of One-Time Passwords (OTPs). This could allow an attacker with access to the database to recover some or all encrypted values.
CVE-2024-23579 2024-07-03 N/A 6.5 MEDIUM
HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of security questions. This could allow an attacker with access to the database to recover some or all encrypted values.
CVE-2023-3243 1 Honeywell 2 Alerton Bcm-web, Alerton Bcm-web Firmware 2024-06-04 N/A 9.8 CRITICAL
** UNSUPPORTED WHEN ASSIGNED ** [An attacker can capture an authenticating hash and utilize it to create new sessions. The hash is also a poorly salted MD5 hash, which could result in a successful brute force password attack. Impacted product is BCM-WEB version 3.3.X. Recommended fix: Upgrade to a supported product such as Alerton ACM.] Out of an abundance of caution, this CVE ID is being assigned to better serve our customers and ensure all who are still running this product understand that the product is end of life and should be removed or upgraded. 
CVE-2024-28974 2024-05-29 N/A 7.6 HIGH
Dell Data Protection Advisor, version(s) 19.9, contain(s) an Inadequate Encryption Strength vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
CVE-2023-35332 1 Microsoft 12 Windows 10 1507, Windows 10 1607, Windows 10 1809 and 9 more 2024-05-29 N/A 6.8 MEDIUM
Windows Remote Desktop Protocol Security Feature Bypass
CVE-2024-20692 1 Microsoft 14 Windows 10 1507, Windows 10 1607, Windows 10 1809 and 11 more 2024-05-29 N/A 5.7 MEDIUM
Microsoft Local Security Authority Subsystem Service Information Disclosure Vulnerability
CVE-2024-0220 2024-05-27 N/A 8.3 HIGH
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
CVE-2023-7237 1 Lantronix 2 Xport Edge, Xport Edge Firmware 2024-05-17 N/A 7.5 HIGH
Lantronix XPort sends weakly encoded credentials within web request headers.
CVE-2023-37397 1 Ibm 1 Aspera Faspex 2024-04-30 N/A 4.4 MEDIUM
IBM Aspera Faspex 5.0.0 through 5.0.7 could allow a local user to obtain or modify sensitive information due to improper encryption of certain data. IBM X-Force ID: 259672.
CVE-2022-40745 1 Ibm 1 Aspera Faspex 2024-04-29 N/A 5.5 MEDIUM
IBM Aspera Faspex 5.0.0 through 5.0.7 could allow a local user to obtain sensitive information due to weaker than expected security. IBM X-Force ID: 236452.
CVE-2023-28896 1 Preh 2 Mib3, Mib3 Firmware 2024-04-24 N/A 2.4 LOW
Access to critical Unified Diagnostics Services (UDS) of the Modular Infotainment Platform 3 (MIB3) infotainment is transmitted via Controller Area Network (CAN) bus in a form that can be easily decoded by attackers with physical access to the vehicle. Vulnerability discovered on Škoda Superb III (3V3) - 2.0 TDI manufactured in 2022.
CVE-2024-29969 2024-04-19 N/A 7.5 HIGH
When a Brocade SANnav installation is upgraded from Brocade SANnav v2.2.2 to Brocade SANnav 2.3.0, TLS/SSL weak message authentication code ciphers are added by default for port 18082.
CVE-2024-29951 2024-04-18 N/A 5.7 MEDIUM
Brocade SANnav before v2.3.1 and v2.3.0a uses the SHA-1 hash in internal SSH ports that are not open to remote connection.
CVE-2024-29950 2024-04-17 N/A 7.5 HIGH
The class FileTransfer implemented in Brocade SANnav before v2.3.1, v2.3.0a, uses the ssh-rsa signature scheme, which has a SHA-1 hash. The vulnerability could allow a remote, unauthenticated attacker to perform a man-in-the-middle attack.
CVE-2024-3387 2024-04-10 N/A 5.3 MEDIUM
A weak (low bit strength) device certificate in Palo Alto Networks Panorama software enables an attacker to perform a meddler-in-the-middle (MitM) attack to capture encrypted traffic between the Panorama management server and the firewalls it manages. With sufficient computing resources, the attacker could break encrypted communication and expose sensitive information that is shared between the management server and the firewalls.