Vulnerabilities (CVE)

Filtered by CWE-319
Total 624 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-5503 1 Netapp 1 Oncommand Workflow Automation 2020-08-24 5.0 MEDIUM 5.3 MEDIUM
OnCommand Workflow Automation versions prior to 5.0 shipped without certain HTTP Security headers configured which could allow an attacker to obtain sensitive information via unspecified vectors.
CVE-2019-11220 1 Ilnkp2p Project 1 Ilnkp2p 2020-08-24 4.3 MEDIUM 8.1 HIGH
An authentication flaw in Shenzhen Yunni Technology iLnkP2P allows remote attackers to actively intercept user-to-device traffic in cleartext, including video streams and device credentials.
CVE-2019-15135 1 Omg 1 Dds Security 2020-08-24 5.0 MEDIUM 7.5 HIGH
The handshake protocol in Object Management Group (OMG) DDS Security 1.1 sends cleartext information about all of the capabilities of a participant (including capabilities inapplicable to the current session), which makes it easier for attackers to discover potentially sensitive reachability information on a Data Distribution Service (DDS) network.
CVE-2019-1010260 1 Ktlint Project 1 Ktlint 2020-08-24 9.3 HIGH 8.1 HIGH
Using ktlint to download and execute custom rulesets can result in arbitrary code execution as the served jars can be compromised by a MITM. This attack is exploitable via Man in the Middle of the HTTP connection to the artifact servers. This vulnerability appears to have been fixed in 0.30.0 and later; after commit 5e547b287d6c260d328a2cb658dbe6b7a7ff2261.
CVE-2020-15954 2 Debian, Kde 2 Debian Linux, Kmail 2020-07-30 4.3 MEDIUM 6.5 MEDIUM
KDE KMail 19.12.3 (aka 5.13.3) engages in unencrypted POP3 communication during times when the UI indicates that encryption is in use.
CVE-2020-4397 1 Ibm 1 Verify Gateway 2020-07-24 4.3 MEDIUM 5.9 MEDIUM
IBM Verify Gateway (IVG) 1.0.0 and 1.0.1 transmits sensitive information in plain text which could be obtained by an attacker using man in the middle techniques. IBM X-Force ID: 179428.
CVE-2020-7592 1 Siemens 9 Simatic Hmi Basic Panels 1st Generation, Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Comfort Panels and 6 more 2020-07-22 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
CVE-2020-12048 1 Baxter 2 Phoenix X36, Phoenix X36 Firmware 2020-07-16 5.0 MEDIUM 7.5 HIGH
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.
CVE-2020-14171 1 Atlassian 1 Bitbucket 2020-07-15 5.8 MEDIUM 6.5 MEDIUM
Atlassian Bitbucket Server from version 4.9.0 before version 7.2.4 allows remote attackers to intercept unencrypted repository import requests via a Man-in-the-Middle (MITM) attack.
CVE-2020-12037 1 Baxter 4 Prismaflex, Prismaflex Firmware, Prismax and 1 more 2020-07-14 5.0 MEDIUM 7.5 HIGH
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
CVE-2020-12036 1 Baxter 4 Prismaflex, Prismaflex Firmware, Prismax and 1 more 2020-07-14 5.0 MEDIUM 7.5 HIGH
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
CVE-2020-12040 1 Baxter 2 Sigma Spectrum Infusion System, Sigma Spectrum Infusion System Firmware 2020-07-09 5.0 MEDIUM 9.8 CRITICAL
Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack.
CVE-2020-12008 1 Baxter 4 Em1200, Em1200 Firmware, Em2400 and 1 more 2020-07-08 5.0 MEDIUM 7.5 HIGH
Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI.
CVE-2020-10628 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2020-07-07 5.0 MEDIUM 7.5 HIGH
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.
CVE-2020-10624 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2020-07-07 5.0 MEDIUM 7.5 HIGH
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
CVE-2020-5594 1 Mitsubishielectric 10 Melsec-fx, Melsec-fx Firmware, Melsec-l and 7 more 2020-07-01 7.5 HIGH 9.8 CRITICAL
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
CVE-2020-2013 1 Paloaltonetworks 1 Pan-os 2020-05-18 6.8 MEDIUM 8.8 HIGH
A cleartext transmission of sensitive information vulnerability in Palo Alto Networks PAN-OS Panorama that discloses an authenticated PAN-OS administrator's PAN-OS session cookie. When an administrator issues a context switch request into a managed firewall with an affected PAN-OS Panorama version, their PAN-OS session cookie is transmitted over cleartext to the firewall. An attacker with the ability to intercept this network traffic between the firewall and Panorama can access the administrator's account and further manipulate devices managed by Panorama. This issue affects: PAN-OS 7.1 versions earlier than 7.1.26; PAN-OS 8.1 versions earlier than 8.1.13; PAN-OS 9.0 versions earlier than 9.0.6; PAN-OS 9.1 versions earlier than 9.1.1; All version of PAN-OS 8.0;
CVE-2020-4092 1 Hcltech 1 Hcl Nomad 2020-05-12 5.0 MEDIUM 5.3 MEDIUM
"If port encryption is not enabled on the Domino Server, HCL Nomad on Android and iOS Platforms will communicate in clear text and does not currently have a user interface option to change the setting to request an encrypted communication channel with the Domino server. This can potentially expose sensitive information including but not limited to server names, user IDs and document content."
CVE-2011-3022 1 Google 1 Chrome 2020-04-16 5.0 MEDIUM N/A
translate/translate_manager.cc in Google Chrome before 17.0.963.56 and 19.x before 19.0.1036.7 uses an HTTP session to exchange data for translation, which allows remote attackers to obtain sensitive information by sniffing the network.
CVE-2020-6997 1 Moxa 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more 2020-03-26 5.0 MEDIUM 7.5 HIGH
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext.