Total
624 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-30993 | 3 Acronis, Linux, Microsoft | 3 Cyber Protect, Linux Kernel, Windows | 2022-06-01 | 5.0 MEDIUM | 7.5 HIGH |
Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240 | |||||
CVE-2022-29874 | 1 Siemens | 72 7kg8500-0aa00-0aa0, 7kg8500-0aa00-0aa0 Firmware, 7kg8500-0aa00-2aa0 and 69 more | 2022-05-26 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not encrypt web traffic with clients but communicate in cleartext via HTTP. This could allow an unauthenticated attacker to capture the traffic and interfere with the functionality of the device. | |||||
CVE-2020-14093 | 4 Canonical, Debian, Mutt and 1 more | 4 Ubuntu Linux, Debian Linux, Mutt and 1 more | 2022-04-27 | 4.3 MEDIUM | 5.9 MEDIUM |
Mutt before 1.14.3 allows an IMAP fcc/postpone man-in-the-middle attack via a PREAUTH response. | |||||
CVE-2020-5867 | 2 F5, Netapp | 2 Nginx Controller, Cloud Backup | 2022-04-26 | 6.8 MEDIUM | 8.1 HIGH |
In versions prior to 3.3.0, the NGINX Controller Agent installer script 'install.sh' uses HTTP instead of HTTPS to check and install packages | |||||
CVE-2020-5865 | 2 F5, Netapp | 2 Nginx Controller, Cloud Backup | 2022-04-26 | 5.8 MEDIUM | 4.8 MEDIUM |
In versions prior to 3.3.0, the NGINX Controller is configured to communicate with its Postgres database server over unencrypted channels, making the communicated data vulnerable to interception via man-in-the-middle (MiTM) attacks. | |||||
CVE-2021-26560 | 1 Synology | 7 Diskstation Manager, Diskstation Manager Unified Controller, Skynas and 4 more | 2022-04-26 | 5.8 MEDIUM | 7.4 HIGH |
Cleartext transmission of sensitive information vulnerability in synoagentregisterd in Synology DiskStation Manager (DSM) before 6.2.3-25426-3 allows man-in-the-middle attackers to spoof servers via an HTTP session. | |||||
CVE-2021-26564 | 1 Synology | 7 Diskstation Manager, Diskstation Manager Unified Controller, Skynas and 4 more | 2022-04-26 | 5.8 MEDIUM | 8.7 HIGH |
Cleartext transmission of sensitive information vulnerability in synorelayd in Synology DiskStation Manager (DSM) before 6.2.3-25426-3 allows man-in-the-middle attackers to spoof servers via an HTTP session. | |||||
CVE-2019-15635 | 1 Grafana | 1 Grafana | 2022-04-22 | 4.0 MEDIUM | 4.9 MEDIUM |
An issue was discovered in Grafana 5.4.0. Passwords for data sources used by Grafana (e.g., MySQL) are not encrypted. An admin user can reveal passwords for any data source by pressing the "Save and test" button within a data source's settings menu. When watching the transaction with Burp Proxy, the password for the data source is revealed and sent to the server. From a browser, a prompt to save the credentials is generated, and the password can be revealed by simply checking the "Show password" box. | |||||
CVE-2021-40392 | 1 Moxa | 1 Mxview | 2022-04-22 | 5.0 MEDIUM | 7.5 HIGH |
An information disclosure vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. Network sniffing can lead to a disclosure of sensitive information. An attacker can sniff network traffic to exploit this vulnerability. | |||||
CVE-2021-45894 | 1 Zauner | 1 Arc | 2022-04-14 | 2.6 LOW | 5.9 MEDIUM |
An issue was discovered in Softwarebuero Zauner ARC 4.2.0.4. There is Cleartext Transmission of Sensitive Information. | |||||
CVE-2021-32982 | 1 Automationdirect | 40 C0-10are-d, C0-10are-d Firmware, C0-10dd1e-d and 37 more | 2022-04-13 | 5.0 MEDIUM | 7.5 HIGH |
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange. | |||||
CVE-2019-8632 | 1 Apple | 1 Texture | 2022-04-12 | 4.0 MEDIUM | 6.5 MEDIUM |
Some analytics data was sent using HTTP rather than HTTPS. This was addressed by no longer sending this analytics data. This issue is fixed in Texture 5.11.10 for iOS, Texture 4.22.0.4 for Android. An attacker in a privileged network position may be able to intercept analytics data. | |||||
CVE-2021-33022 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-04-08 | 5.0 MEDIUM | 7.5 HIGH |
Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. | |||||
CVE-2019-10732 | 2 Debian, Kde | 2 Debian Linux, Kmail | 2022-04-05 | 4.3 MEDIUM | 4.3 MEDIUM |
In KDE KMail 5.2.3, an attacker in possession of S/MIME or PGP encrypted emails can wrap them as sub-parts within a crafted multipart email. The encrypted part(s) can further be hidden using HTML/CSS or ASCII newline characters. This modified multipart email can be re-sent by the attacker to the intended receiver. If the receiver replies to this (benign looking) email, they unknowingly leak the plaintext of the encrypted message part(s) back to the attacker. | |||||
CVE-2020-25178 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2022-04-04 | 9.3 HIGH | 8.8 HIGH |
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files. | |||||
CVE-2019-16672 | 1 Weidmueller | 80 Ie-sw-pl08m-6tx-2sc, Ie-sw-pl08m-6tx-2sc Firmware, Ie-sw-pl08m-6tx-2scs and 77 more | 2022-04-01 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext. | |||||
CVE-2022-0988 | 1 Deltaww | 1 Diaenergie | 2022-04-01 | 5.0 MEDIUM | 7.5 HIGH |
Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product. | |||||
CVE-2021-45100 | 3 Ksmbd Project, Linux, Netapp | 18 Ksmbd, Linux Kernel, H300e and 15 more | 2022-03-29 | 5.0 MEDIUM | 7.5 HIGH |
The ksmbd server through 3.4.2, as used in the Linux kernel through 5.15.8, sometimes communicates in cleartext even though encryption has been enabled. This occurs because it sets the SMB2_GLOBAL_CAP_ENCRYPTION flag when using the SMB 3.1.1 protocol, which is a violation of the SMB protocol specification. When Windows 10 detects this protocol violation, it disables encryption. | |||||
CVE-2021-40846 | 1 Tradingpaints | 1 Trading Paints | 2022-03-15 | 7.6 HIGH | 7.5 HIGH |
An issue was discovered in Rhinode Trading Paints through 2.0.36. TP Updater.exe uses cleartext HTTP to check, and request, updates. Thus, attackers can man-in-the-middle a victim to download a malicious binary in place of the real update, with no SSL errors or warnings. | |||||
CVE-2022-21798 | 1 Ge | 1 Cimplicity | 2022-03-08 | 7.5 HIGH | 9.8 CRITICAL |
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system. |