CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-22906 1 Heroelectronix 4 Qubo Hcd01, Qubo Hcd01 Firmware, Qubo Hcd02 and 1 more 2023-07-10 N/A 8.8 HIGH
Hero Qubo HCD01_02_V1.38_20220125 devices allow TELNET access with root privileges by default, without a password.
CVE-2023-36347 1 Codekop 1 Codekop 2023-07-07 N/A 7.5 HIGH
A broken authentication mechanism in the endpoint excel.php of POS Codekop v2.0 allows unauthenticated attackers to download selling data.
CVE-2022-24820 1 Xwiki 1 Xwiki 2023-07-06 4.3 MEDIUM 5.3 MEDIUM
XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. A guest user without the right to view pages of the wiki can still list documents by rendering some velocity documents. The problem has been patched in XWiki versions 12.10.11, 13.4.4, and 13.9-rc-1. There is no known workaround for this problem.
CVE-2022-21816 1 Nvidia 2 Cloud Gaming Virtual Gpu, Virtual Gpu 2023-07-03 4.9 MEDIUM 5.5 MEDIUM
NVIDIA vGPU software contains a vulnerability in the Virtual GPU Manager (nvidia.ko), where a user in the guest OS can cause a GPU interrupt storm on the hypervisor host, leading to a denial of service.
CVE-2022-23719 1 Pingidentity 1 Pingid Integration For Windows Login 2023-07-03 6.9 MEDIUM 6.4 MEDIUM
PingID Windows Login prior to 2.8 does not authenticate communication with a local Java service used to capture security key requests. An attacker with the ability to execute code on the target machine maybe able to exploit and spoof the local Java service using multiple attack vectors. A successful attack can lead to code executed as SYSTEM by the PingID Windows Login application, or even a denial of service for offline security key authentication.
CVE-2022-28809 1 Opendesign 1 Drawings Sdk 2023-06-30 N/A 7.8 HIGH
An issue was discovered in Open Design Alliance Drawings SDK before 2023.3. An Out-of-Bounds Read vulnerability exists when reading a DWG file with an invalid vertex number in a recovery mode. An attacker can leverage this vulnerability to execute code in the context of the current process.
CVE-2023-27396 1 Omron 542 Cj2h-cpu64, Cj2h-cpu64-eip, Cj2h-cpu64-eip Firmware and 539 more 2023-06-30 N/A 9.8 CRITICAL
FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)
CVE-2023-31411 1 Sick 1 Sick Eventcam App 2023-06-29 N/A 9.8 CRITICAL
A remote unprivileged attacker can modify and access configuration settings on the EventCam App due to the absence of API authentication. The lack of authentication in the API allows the attacker to potentially compromise the functionality of the EventCam App.
CVE-2022-29883 1 Siemens 72 7kg8500-0aa00-0aa0, 7kg8500-0aa00-0aa0 Firmware, 7kg8500-0aa00-2aa0 and 69 more 2023-06-28 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files without authentication.
CVE-2022-2765 1 Company Website Cms Project 1 Company Website Cms 2023-06-28 N/A 9.8 CRITICAL
A vulnerability was found in SourceCodester Company Website CMS 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /dashboard/settings. The manipulation leads to improper authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-206161 was assigned to this vulnerability.
CVE-2021-20238 1 Redhat 2 Openshift Container Platform, Openshift Machine-config-operator 2023-06-26 4.3 MEDIUM 3.7 LOW
It was found in OpenShift Container Platform 4 that ignition config, served by the Machine Config Server, can be accessed externally from clusters without authentication. The MCS endpoint (port 22623) provides ignition configuration used for bootstrapping Nodes and can include some sensitive data, e.g. registry pull secrets. There are two scenarios where this data can be accessed. The first is on Baremetal, OpenStack, Ovirt, Vsphere and KubeVirt deployments which do not have a separate internal API endpoint and allow access from outside the cluster to port 22623 from the standard OpenShift API Virtual IP address. The second is on cloud deployments when using unsupported network plugins, which do not create iptables rules that prevent to port 22623. In this scenario, the ignition config is exposed to all pods within the cluster and cannot be accessed externally.
CVE-2021-26637 1 Shinasys 6 Sihas Acm-300, Sihas Acm-300 Firmware, Sihas Gcm-300 and 3 more 2023-06-26 7.5 HIGH 9.8 CRITICAL
There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.
CVE-2023-2827 1 Sap 2 Digital Manufacturing, Plant Connectivity 2023-06-26 N/A 5.7 MEDIUM
SAP Plant Connectivity - version 15.5 (PCo) or the Production Connector for SAP Digital Manufacturing - version 1.0, do not validate the signature of the JSON Web Token (JWT) in the HTTP request sent from SAP Digital Manufacturing. Therefore, unauthorized callers from the internal network could send service requests to PCo or the Production Connector, which could have an impact on the integrity of the integration with SAP Digital Manufacturing.
CVE-2022-46145 1 Goauthentik 1 Authentik 2023-06-23 N/A 9.8 CRITICAL
authentik is an open-source identity provider. Versions prior to 2022.11.2 and 2022.10.2 are vulnerable to unauthorized user creation and potential account takeover. With the default flows, unauthenticated users can create new accounts in authentik. If a flow exists that allows for email-verified password recovery, this can be used to overwrite the email address of admin accounts and take over their accounts. authentik 2022.11.2 and 2022.10.2 fix this issue. As a workaround, a policy can be created and bound to the `default-user-settings-flow flow` with the contents `return request.user.is_authenticated`.
CVE-2023-31196 1 Inaba 16 Ac-pd-wapu, Ac-pd-wapu-p, Ac-pd-wapu-p Firmware and 13 more 2023-06-22 N/A 7.5 HIGH
Missing authentication for critical function in Wi-Fi AP UNIT allows a remote unauthenticated attacker to obtain sensitive information of the affected products. Affected products and versions are as follows: AC-PD-WAPU v1.05_B04 and earlier, AC-PD-WAPUM v1.05_B04 and earlier, AC-PD-WAPU-P v1.05_B04P and earlier, AC-PD-WAPUM-P v1.05_B04P and earlier, AC-WAPU-300 v1.00_B07 and earlier, AC-WAPUM-300 v1.00_B07 and earlier, AC-WAPU-300-P v1.00_B07 and earlier, and AC-WAPUM-300-P v1.00_B07 and earlier
CVE-2023-34335 1 Ami 1 Megarac Spx 2023-06-20 N/A 9.1 CRITICAL
AMI BMC contains a vulnerability in the IPMI handler, where an unauthenticated host is allowed to write to a host SPI flash, bypassing secure boot protections. An exploitation of this vulnerability may lead to a loss of integrity or denial of service.  
CVE-2023-2187 1 Trianglemicroworks 1 Scada Data Gateway 2023-06-16 N/A 5.3 MEDIUM
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
CVE-2023-34094 1 Chuanhuchatgpt Project 1 Chuanhuchatgpt 2023-06-16 N/A 5.3 MEDIUM
ChuanhuChatGPT is a graphical user interface for ChatGPT and many large language models. A vulnerability in versions 20230526 and prior allows unauthorized access to the config.json file of the privately deployed ChuanghuChatGPT project, when authentication is not configured. The attacker can exploit this vulnerability to steal the API keys in the configuration file. The vulnerability has been fixed in commit bfac445. As a workaround, setting up access authentication can help mitigate the vulnerability.
CVE-2018-4834 1 Siemens 10 Pxc001-e.d, Pxc001-e.d Firmware, Pxc00\/50\/100\/200-e.d and 7 more 2023-06-13 10.0 HIGH 9.8 CRITICAL
A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions < V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions < V4.10.111), Desigo PXC001-E.D V5.00 (All versions < V5.0.171), Desigo PXC001-E.D V5.10 (All versions < V5.10.69), Desigo PXC001-E.D V6.00 (All versions < V6.0.204), Desigo PXC100-E.D V4.10 (All versions < V4.10.111), Desigo PXC100-E.D V5.00 (All versions < V5.0.171), Desigo PXC100-E.D V5.10 (All versions < V5.10.69), Desigo PXC100-E.D V6.00 (All versions < V6.0.204), Desigo PXC12-E.D V4.10 (All versions < V4.10.111), Desigo PXC12-E.D V5.00 (All versions < V5.0.171), Desigo PXC12-E.D V5.10 (All versions < V5.10.69), Desigo PXC12-E.D V6.00 (All versions < V6.0.204), Desigo PXC200-E.D V4.10 (All versions < V4.10.111), Desigo PXC200-E.D V5.00 (All versions < V5.0.171), Desigo PXC200-E.D V5.10 (All versions < V5.10.69), Desigo PXC200-E.D V6.00 (All versions < V6.0.204), Desigo PXC22-E.D V4.10 (All versions < V4.10.111), Desigo PXC22-E.D V5.00 (All versions < V5.0.171), Desigo PXC22-E.D V5.10 (All versions < V5.10.69), Desigo PXC22-E.D V6.00 (All versions < V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC50-E.D V4.10 (All versions < V4.10.111), Desigo PXC50-E.D V5.00 (All versions < V5.0.171), Desigo PXC50-E.D V5.10 (All versions < V5.10.69), Desigo PXC50-E.D V6.00 (All versions < V6.0.204), Desigo PXM20-E V4.10 (All versions < V4.10.111), Desigo PXM20-E V5.00 (All versions < V5.0.171), Desigo PXM20-E V5.10 (All versions < V5.10.69), Desigo PXM20-E V6.00 (All versions < V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication.
CVE-2023-30604 1 Hitrontech 2 Coda-5310, Coda-5310 Firmware 2023-06-09 N/A 9.8 CRITICAL
It is identified a vulnerability of insufficient authentication in the system configuration interface of Hitron Technologies CODA-5310. An unauthorized remote attacker can exploit this vulnerability to access system configuration interface, resulting in performing arbitrary system operation or disrupt service.