CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-0053 1 Juniper 2 Junos, Vsrx 2019-10-09 7.2 HIGH 6.8 MEDIUM
An authentication bypass vulnerability in the initial boot sequence of Juniper Networks Junos OS on vSRX Series may allow an attacker to gain full control of the system without authentication when the system is initially booted up. Affected releases are Juniper Networks Junos OS: 15.1X49 versions prior to 15.1X49-D30 on vSRX.
CVE-2018-0052 1 Juniper 8 Ex2300, Ex3400, Junos and 5 more 2019-10-09 9.3 HIGH 8.1 HIGH
If RSH service is enabled on Junos OS and if the PAM authentication is disabled, a remote unauthenticated attacker can obtain root access to the device. RSH service is disabled by default on Junos. There is no documented CLI command to enable this service. However, an undocumented CLI command allows a privileged Junos user to enable RSH service and disable PAM, and hence expose the system to unauthenticated root access. When RSH is enabled, the device is listing to RSH connections on port 514. This issue is not exploitable on platforms where Junos release is based on FreeBSD 10+. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D75 on SRX Series; 14.1X53 versions prior to 14.1X53-D47 on QFX/EX Series; 15.1 versions prior to 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D131, 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D59 on EX2300/EX3400 Series; 15.1X53 versions prior to 15.1X53-D67 on QFX10K Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D471, 15.1X53-D490 on NFX Series; 16.1 versions prior to 16.1R3-S9, 16.1R4-S9, 16.1R5-S4, 16.1R6-S4, 16.1R7; 16.2 versions prior to 16.2R2-S5; 17.1 versions prior to 17.1R1-S7, 17.1R2-S7, 17.1R3; 17.2 versions prior to 17.2R1-S6, 17.2R2-S4, 17.2R3; 17.2X75 versions prior to 17.2X75-D110, 17.2X75-D91; 17.3 versions prior to 17.3R1-S4, 17.3R2-S2, 17.3R3; 17.4 versions prior to 17.4R1-S3, 17.4R2; 18.2X75 versions prior to 18.2X75-D5.
CVE-2018-0044 1 Juniper 3 Junos, Nfx150, Nfx250 2019-10-09 6.8 MEDIUM 8.1 HIGH
An insecure SSHD configuration in Juniper Device Manager (JDM) and host OS on Juniper NFX Series devices may allow remote unauthenticated access if any of the passwords on the system are empty. The affected SSHD configuration has the PermitEmptyPasswords option set to "yes". Affected releases are Juniper Networks Junos OS: 18.1 versions prior to 18.1R4 on NFX Series.
CVE-2017-9939 1 Siemens 1 Sipass Integrated 2019-10-09 7.5 HIGH 9.8 CRITICAL
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.
CVE-2017-9630 1 Pdqinc 22 Laserjet, Laserjet Firmware, Laserwash 360 and 19 more 2019-10-09 7.5 HIGH 9.4 CRITICAL
An Improper Authentication issue was discovered in PDQ Manufacturing LaserWash G5 and G5 S Series all versions, LaserWash M5, all versions, LaserWash 360 and 360 Plus, all versions, LaserWash AutoXpress and AutoExpress Plus, all versions, LaserJet, all versions, ProTouch Tandem, all versions, ProTouch ICON, all versions, and ProTouch AutoGloss, all versions. The web server does not properly verify that provided authentication information is correct.
CVE-2017-9625 1 Envitech 1 Envidas Ultimate 2019-10-09 6.4 MEDIUM 8.2 HIGH
An Improper Authentication issue was discovered in Envitech EnviDAS Ultimate Versions prior to v1.0.0.5. The web application lacks proper authentication which could allow an attacker to view information and modify settings or execute code remotely.
CVE-2017-9552 1 Synology 1 Photo Station 2019-10-09 2.1 LOW 7.8 HIGH
A design flaw in authentication in Synology Photo Station 6.0-2528 through 6.7.1-3419 allows local users to obtain credentials via cmdline. Synology Photo Station employs the synophoto_dsm_user program to authenticate username and password by "synophoto_dsm_user --auth USERNAME PASSWORD", and local users are able to obtain credentials by sniffing "/proc/*/cmdline".
CVE-2017-7937 1 Phoenix Contact Gmbh 2 Mguard, Mguard Firmware 2019-10-09 4.3 MEDIUM 4.0 MEDIUM
An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may be able to gain unauthorized access to the user firewall when RADIUS servers are unreachable.
CVE-2017-7934 1 Osisoft 1 Pi Data Archive 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Network Manager using older protocol versions contains a flaw that could allow a malicious user to authenticate with a server and then cause PI Network Manager to behave in an undefined manner.
CVE-2017-7931 1 Abb 2 Ip Gateway, Ip Gateway Firmware 2019-10-09 7.5 HIGH 9.8 CRITICAL
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
CVE-2017-7930 1 Osisoft 1 Pi Data Archive 2019-10-09 5.8 MEDIUM 7.4 HIGH
An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Data Archive has protocol flaws with the potential to expose change records in the clear and allow a malicious party to spoof a server within a collective.
CVE-2017-7920 1 Abb 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more 2019-10-09 5.0 MEDIUM 7.5 HIGH
An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
CVE-2017-7919 1 Newport 4 Xps-cx, Xps-cx Firmware, Xps-qx and 1 more 2019-10-09 7.5 HIGH 9.8 CRITICAL
An Improper Authentication issue was discovered in Newport XPS-Cx and XPS-Qx. An attacker may bypass authentication by accessing a specific uniform resource locator (URL).
CVE-2017-7912 1 Hanwhasecurity 2 Srn-4000, Srn-4000 Firmware 2019-10-09 7.5 HIGH 9.8 CRITICAL
Hanwha Techwin SRN-4000, SRN-4000 firmware versions prior to SRN4000_v2.16_170401, A specially crafted http request and response could allow an attacker to gain access to the device management page with admin privileges without proper authentication.
CVE-2017-7909 1 Advantech B\+b Smartworx 2 Mesr901, Mesr901 Firmware 2019-10-09 7.5 HIGH 9.8 CRITICAL
A Use of Client-Side Authentication issue was discovered in Advantech B+B SmartWorx MESR901 firmware versions 1.5.2 and prior. The web interface uses JavaScript to check client authentication and redirect unauthorized users. Attackers may intercept requests and bypass authentication to access restricted web pages.
CVE-2017-7557 1 Powerdns 1 Dnsdist 2019-10-09 6.8 MEDIUM 8.8 HIGH
dnsdist version 1.1.0 is vulnerable to a flaw in authentication mechanism for REST API potentially allowing CSRF attack.
CVE-2017-7546 2 Debian, Postgresql 2 Debian Linux, Postgresql 2019-10-09 7.5 HIGH 9.8 CRITICAL
PostgreSQL versions before 9.2.22, 9.3.18, 9.4.13, 9.5.8 and 9.6.4 are vulnerable to incorrect authentication flaw allowing remote attackers to gain access to database accounts with an empty password.
CVE-2017-6871 1 Siemens 2 Simatic Wincc Sm\@rtclient, Simatic Wincc Sm\@rtclient Lite 2019-10-09 4.6 MEDIUM 5.4 MEDIUM
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions.
CVE-2017-6869 1 Siemens 1 Viewport For Web Office Portal 2019-10-09 10.0 HIGH 9.8 CRITICAL
A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the operating-system user running the web server by sending specially crafted network packets to port 443/TCP or port 80/TCP.
CVE-2017-6747 1 Cisco 1 Identity Services Engine 2019-10-09 7.5 HIGH 9.8 CRITICAL
A vulnerability in the authentication module of Cisco Identity Services Engine (ISE) could allow an unauthenticated, remote attacker to bypass local authentication. The vulnerability is due to improper handling of authentication requests and policy assignment for externally authenticated users. An attacker could exploit this vulnerability by authenticating with a valid external user account that matches an internal username and incorrectly receiving the authorization policy of the internal account. An exploit could allow the attacker to have Super Admin privileges for the ISE Admin portal. This vulnerability does not affect endpoints authenticating to the ISE. The vulnerability affects Cisco ISE, Cisco ISE Express, and Cisco ISE Virtual Appliance running Release 1.3, 1.4, 2.0.0, 2.0.1, or 2.1.0. Release 2.2.x is not affected. Cisco Bug IDs: CSCvb10995.