Total
2377 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-26471 | 1 Xwiki | 1 Xwiki | 2023-03-13 | N/A | 8.8 HIGH |
XWiki Platform is a generic wiki platform. Starting in version 11.6-rc-1, comments are supposed to be executed with the right of superadmin but in restricted mode (anything dangerous is disabled), but the async macro does not take into account the restricted mode. This means that any user with comment right can use the async macro to make it execute any wiki content with the right of superadmin. This has been patched in XWiki 14.9, 14.4.6, and 13.10.10. The only known workaround consists of applying a patch and rebuilding and redeploying `org.xwiki.platform:xwiki-platform-rendering-async-macro`. | |||||
CVE-2014-8183 | 2 Redhat, Theforeman | 2 Satellite, Foreman | 2023-03-03 | 6.5 MEDIUM | 7.4 HIGH |
It was found that foreman, versions 1.x.x before 1.15.6, in Satellite 6 did not properly enforce access controls on certain resources. An attacker with access to the API and knowledge of the resource name can access resources in other organizations. | |||||
CVE-2023-22920 | 1 Zyxel | 4 Lte3202-m437, Lte3202-m437 Firmware, Lte3316-m604 and 1 more | 2023-03-02 | N/A | 9.8 CRITICAL |
A security misconfiguration vulnerability exists in the Zyxel LTE3316-M604 firmware version V2.00(ABMP.6)C0 due to a factory default misconfiguration intended for testing purposes. A remote attacker could leverage this vulnerability to access an affected device using Telnet. | |||||
CVE-2018-7364 | 1 Zte | 1 Zxin10 | 2023-03-01 | 10.0 HIGH | 9.8 CRITICAL |
All versions up to ZXINOS-RESV1.01.43 of the ZTE ZXIN10 product European region are impacted by improper access control vulnerability. Due to improper access control to devcomm process, an unauthorized remote attacker can exploit this vulnerability to execute arbitrary code with root privileges. | |||||
CVE-2018-19577 | 1 Gitlab | 1 Gitlab | 2023-03-01 | 5.0 MEDIUM | 5.3 MEDIUM |
Gitlab CE/EE, versions 8.6 up to 11.x before 11.3.11, 11.4 before 11.4.8, and 11.5 before 11.5.1, are vulnerable to an incorrect access control vulnerability that displays to an unauthorized user the title and namespace of a confidential issue. | |||||
CVE-2018-3762 | 1 Nextcloud | 1 Nextcloud Server | 2023-02-28 | 4.0 MEDIUM | 4.3 MEDIUM |
Nextcloud Server before 12.0.8 and 13.0.3 suffers from improper checks of dropped permissions for incoming shares allowing a user to still request previews for files it should not have access to. | |||||
CVE-2023-24484 | 1 Citrix | 1 Workspace | 2023-02-24 | N/A | 5.5 MEDIUM |
A malicious user can cause log files to be written to a directory that they do not have permission to write to. | |||||
CVE-2023-24485 | 1 Citrix | 1 Workspace | 2023-02-24 | N/A | 7.8 HIGH |
Vulnerabilities have been identified that, collectively, allow a standard Windows user to perform operations as SYSTEM on the computer running Citrix Workspace app. | |||||
CVE-2022-32212 | 4 Debian, Fedoraproject, Nodejs and 1 more | 4 Debian Linux, Fedora, Node.js and 1 more | 2023-02-23 | N/A | 8.1 HIGH |
A OS Command Injection vulnerability exists in Node.js versions <14.20.0, <16.20.0, <18.5.0 due to an insufficient IsAllowedHost check that can easily be bypassed because IsIPAddress does not properly check if an IP address is invalid before making DBS requests allowing rebinding attacks. | |||||
CVE-2023-25161 | 1 Nextcloud | 1 Nextcloud Server | 2023-02-23 | N/A | 5.3 MEDIUM |
Nextcloud Server is the file server software for Nextcloud, a self-hosted productivity platform. Nextcloud Server and Nextcloud Enterprise Server prior to versions 25.0.1 24.0.8, and 23.0.12 missing rate limiting on password reset functionality. This could result in service slowdown, storage overflow, or cost impact when using external email services. Users should upgrade to Nextcloud Server 25.0.1, 24.0.8, or 23.0.12 or Nextcloud Enterprise Server 25.0.1, 24.0.8, or 23.0.12 to receive a patch. No known workarounds are available. | |||||
CVE-2023-23835 | 1 Mendix | 1 Mendix | 2023-02-22 | N/A | 7.5 HIGH |
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors. | |||||
CVE-2023-21438 | 1 Samsung | 1 Android | 2023-02-21 | N/A | 2.4 LOW |
Improper logic in HomeScreen prior to SMR Feb-2023 Release 1 allows physical attacker to access App preview protected by Secure Folder. | |||||
CVE-2023-21427 | 1 Samsung | 1 Android | 2023-02-21 | N/A | 6.5 MEDIUM |
Improper access control vulnerability in NfcTile prior to SMR Jan-2023 Release 1 allows to attacker to use NFC without user recognition. | |||||
CVE-2023-21442 | 1 Samsung | 1 Android | 2023-02-21 | N/A | 5.5 MEDIUM |
Improper access control vulnerability in Runestone application prior to version 2.9.09.003 in Android R(11) and 3.2.01.007 in Android S(12) allows local attackers to get device location information. | |||||
CVE-2023-21445 | 1 Samsung | 1 Android | 2023-02-17 | N/A | 7.8 HIGH |
Improper access control vulnerability in MyFiles prior to versions 12.2.09 in Android R(11), 13.1.03.501 in Android S(12) and 14.1.00.422 in Android T(13) allows local attacker to write file with MyFiles privilege via implicit intent. | |||||
CVE-2023-21447 | 1 Samsung | 1 Cloud | 2023-02-17 | N/A | 3.3 LOW |
Improper access control vulnerabilities in Samsung Cloud prior to version 5.3.0.32 allows local attackers to access information with Samsung Cloud's privilege via implicit intent. | |||||
CVE-2023-25150 | 1 Nextcloud | 1 Richdocuments | 2023-02-16 | N/A | 5.7 MEDIUM |
Nextcloud office/richdocuments is an office suit for the nextcloud server platform. In affected versions the Collabora integration can be tricked to provide access to any file without proper permission validation. As a result any user with access to Collabora can obtain the content of other users files. It is recommended that the Nextcloud Office App (Collabora Integration) is updated to 7.0.2 (Nextcloud 25), 6.3.2 (Nextcloud 24), 5.0.10 (Nextcloud 23), 4.2.9 (Nextcloud 21-22), or 3.8.7 (Nextcloud 15-20). There are no known workarounds for this issue. | |||||
CVE-2014-6195 | 4 Ibm, Linux, Microsoft and 1 more | 7 Aix, Linux On Ibm Z, Tivoli Storage Manager and 4 more | 2023-02-14 | 1.9 LOW | N/A |
The (1) Java GUI and (2) Web GUI components in the IBM Tivoli Storage Manager (TSM) Backup-Archive client 5.4 and 5.5 before 5.5.4.4 on AIX, Linux, and Solaris; 5.4.x and 5.5.x on Windows and z/OS; 6.1 before 6.1.5.7 on z/OS; 6.1 and 6.2 before 6.2.5.2 on Windows, before 6.2.5.3 on AIX and Linux x86, and before 6.2.5.4 on Linux Z and Solaris; 6.3 before 6.3.2.1 on AIX, before 6.3.2.2 on Windows, and before 6.3.2.3 on Linux; 6.4 before 6.4.2.1; and 7.1 before 7.1.1 in IBM TSM for Mail, when the Data Protection for Lotus Domino component is used, allow local users to bypass authentication and restore a Domino database or transaction-log backup via unspecified vectors. | |||||
CVE-2023-23615 | 1 Discourse | 1 Discourse | 2023-02-14 | N/A | 5.3 MEDIUM |
Discourse is an open source discussion platform. The embeddable comments can be exploited to create new topics as any user but without any clear title or content. This issue is patched in the latest stable, beta and tests-passed versions of Discourse. As a workaround, disable embeddable comments by deleting all embeddable hosts. | |||||
CVE-2019-6810 | 1 Schneider-electric | 2 Bmxnor0200h, Bmxnor0200h Firmware | 2023-02-13 | 6.5 MEDIUM | 8.8 HIGH |
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol. |