Total
8075 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-3391 | 1 Cisco | 1 Digital Network Architecture Center | 2021-08-06 | 4.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability in Cisco Digital Network Architecture (DNA) Center could allow an authenticated, remote attacker to view sensitive information in clear text. The vulnerability is due to insecure storage of certain unencrypted credentials on an affected device. An attacker could exploit this vulnerability by viewing the network device configuration and obtaining credentials that they may not normally have access to. A successful exploit could allow the attacker to use those credentials to discover and manage network devices. | |||||
| CVE-2020-3411 | 1 Cisco | 1 Dna Center | 2021-08-06 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability in Cisco DNA Center software could allow an unauthenticated remote attacker access to sensitive information on an affected system. The vulnerability is due to improper handling of authentication tokens by the affected software. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker access to sensitive device information, which includes configuration files. | |||||
| CVE-2020-3347 | 1 Cisco | 1 Webex Meetings | 2021-08-06 | 2.1 LOW | 5.5 MEDIUM |
| A vulnerability in Cisco Webex Meetings Desktop App for Windows could allow an authenticated, local attacker to gain access to sensitive information on an affected system. The vulnerability is due to unsafe usage of shared memory that is used by the affected software. An attacker with permissions to view system memory could exploit this vulnerability by running an application on the local system that is designed to read shared memory. A successful exploit could allow the attacker to retrieve sensitive information from the shared memory, including usernames, meeting information, or authentication tokens that could aid the attacker in future attacks. | |||||
| CVE-2020-3360 | 1 Cisco | 74 Unified Ip Phone 6901, Unified Ip Phone 6901 Firmware, Unified Ip Phone 6911 and 71 more | 2021-08-06 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability in the Web Access feature of Cisco IP Phones Series 7800 and Series 8800 could allow an unauthenticated, remote attacker to view sensitive information on an affected device. The vulnerability is due to improper access controls on the web-based management interface of an affected device. An attacker could exploit this vulnerability by sending malicious requests to the device, which could allow the attacker to bypass access restrictions. A successful attack could allow the attacker to view sensitive information, including device call logs that contain names, usernames, and phone numbers of users of the device. | |||||
| CVE-2015-4547 | 1 Rsa | 1 Web Threat Detection | 2021-08-06 | 4.0 MEDIUM | N/A |
| EMC RSA Web Threat Detection before 5.1 SP1 stores a cleartext AnnoDB password in a configuration file, which allows remote authenticated users to obtain sensitive information by reading this file. | |||||
| CVE-2014-9225 | 2 Broadcom, Symantec | 2 Symantec Critical System Protection, Data Center Security | 2021-08-04 | 4.0 MEDIUM | N/A |
| The ajaxswing webui in the management server in Symantec Critical System Protection (SCSP) 5.2.9 through MP6 and Symantec Data Center Security: Server Advanced (SDCS:SA) 6.0.x through 6.0 MP1 allows remote authenticated users to obtain sensitive server information via unspecified vectors. | |||||
| CVE-2016-9590 | 2 Openstack, Redhat | 2 Puppet-swift, Openstack | 2021-08-04 | 4.0 MEDIUM | 6.5 MEDIUM |
| puppet-swift before versions 8.2.1, 9.4.4 is vulnerable to an information-disclosure in Red Hat OpenStack Platform director's installation of Object Storage (swift). During installation, the Puppet script responsible for deploying the service incorrectly removes and recreates the proxy-server.conf file with world-readable permissions. | |||||
| CVE-2018-1059 | 3 Canonical, Dpdk, Redhat | 9 Ubuntu Linux, Data Plane Development Kit, Ceph Storage and 6 more | 2021-08-04 | 2.9 LOW | 6.1 MEDIUM |
| The DPDK vhost-user interface does not check to verify that all the requested guest physical range is mapped and contiguous when performing Guest Physical Addresses to Host Virtual Addresses translations. This may lead to a malicious guest exposing vhost-user backend process memory. All versions before 18.02.1 are vulnerable. | |||||
| CVE-2018-14432 | 3 Debian, Openstack, Redhat | 3 Debian Linux, Keystone, Openstack | 2021-08-04 | 3.5 LOW | 5.3 MEDIUM |
| In the Federation component of OpenStack Keystone before 11.0.4, 12.0.0, and 13.0.0, an authenticated "GET /v3/OS-FEDERATION/projects" request may bypass intended access restrictions on listing projects. An authenticated user may discover projects they have no authority to access, leaking all projects in the deployment and their attributes. Only Keystone with the /v3/OS-FEDERATION endpoint enabled via policy.json is affected. | |||||
| CVE-2016-4474 | 1 Redhat | 1 Openstack | 2021-08-04 | 3.3 LOW | 8.8 HIGH |
| The image build process for the overcloud images in Red Hat OpenStack Platform 8.0 (Liberty) director and Red Hat Enterprise Linux OpenStack Platform 7.0 (Kilo) director (aka overcloud-full) use a default root password of ROOTPW, which allows attackers to gain access via unspecified vectors. | |||||
| CVE-2018-16876 | 4 Canonical, Debian, Redhat and 1 more | 10 Ubuntu Linux, Debian Linux, Ansible and 7 more | 2021-08-04 | 3.5 LOW | 5.3 MEDIUM |
| ansible before versions 2.5.14, 2.6.11, 2.7.5 is vulnerable to a information disclosure flaw in vvv+ mode with no_log on that can lead to leakage of sensible data. | |||||
| CVE-2018-10915 | 4 Canonical, Debian, Postgresql and 1 more | 9 Ubuntu Linux, Debian Linux, Postgresql and 6 more | 2021-08-04 | 6.0 MEDIUM | 7.5 HIGH |
| A vulnerability was found in libpq, the default PostgreSQL client library where libpq failed to properly reset its internal state between connections. If an affected version of libpq was used with "host" or "hostaddr" connection parameters from untrusted input, attackers could bypass client-side connection security features, obtain access to higher privileged connections or potentially cause other impact through SQL injection, by causing the PQescape() functions to malfunction. Postgresql versions before 10.5, 9.6.10, 9.5.14, 9.4.19, and 9.3.24 are affected. | |||||
| CVE-2021-22001 | 1 Cloudfoundry | 2 Cf-deployment, User Account And Authentication | 2021-08-04 | 5.0 MEDIUM | 7.5 HIGH |
| In UAA versions prior to 75.3.0, sensitive information like relaying secret of the provider was revealed in response when deletion request of an identity provider( IdP) of type “oauth 1.0” was sent to UAA server. | |||||
| CVE-2021-21587 | 1 Dell | 1 Wyse Management Suite | 2021-07-31 | 2.1 LOW | 3.3 LOW |
| Dell Wyse Management Suite versions 3.2 and earlier contain a full path disclosure vulnerability. A local unauthenticated attacker could exploit this vulnerability in order to obtain the path of files and folders. | |||||
| CVE-2021-22728 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 4.0 MEDIUM | 6.5 MEDIUM |
| A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report. | |||||
| CVE-2021-22721 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 5.0 MEDIUM | 5.3 MEDIUM |
| A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server. | |||||
| CVE-2021-22770 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2021-07-27 | 4.0 MEDIUM | 6.5 MEDIUM |
| A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information. | |||||
| CVE-2002-2435 | 1 Microsoft | 2 Ie, Internet Explorer | 2021-07-23 | 4.3 MEDIUM | N/A |
| The Cascading Style Sheets (CSS) implementation in Microsoft Internet Explorer 8.0 and earlier does not properly handle the :visited pseudo-class, which allows remote attackers to obtain sensitive information about visited web pages via a crafted HTML document, a related issue to CVE-2010-2264. | |||||
| CVE-2011-1713 | 1 Microsoft | 2 Internet Explorer, Windows 7 | 2021-07-23 | 4.3 MEDIUM | N/A |
| Microsoft msxml.dll, as used in Internet Explorer 8 on Windows 7, allows remote attackers to obtain potentially sensitive information about heap memory addresses via an XML document containing a call to the XSLT generate-id XPath function. NOTE: this might overlap CVE-2011-1202. | |||||
| CVE-2009-4073 | 1 Microsoft | 1 Internet Explorer | 2021-07-23 | 5.0 MEDIUM | N/A |
| The printing functionality in Microsoft Internet Explorer 8 allows remote attackers to discover a local pathname, and possibly a local username, by reading the dc:title element of a PDF document that was generated from a local web page. | |||||