CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-12707 | 1 Spidercontrol | 1 Scada Microbrowser | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow. | |||||
CVE-2017-12706 | 1 Advantech | 1 Webaccess | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
A stack-based buffer overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities where there is a lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer, which could allow an attacker to execute arbitrary code under the context of the process. | |||||
CVE-2016-6563 | 1 Dlink | 18 Dir-818l\(w\), Dir-818l\(w\) Firmware, Dir-822 and 15 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
Processing malformed SOAP messages when performing the HNAP Login action causes a buffer overflow in the stack in some D-Link DIR routers. The vulnerable XML fields within the SOAP body are: Action, Username, LoginPassword, and Captcha. The following products are affected: DIR-823, DIR-822, DIR-818L(W), DIR-895L, DIR-890L, DIR-885L, DIR-880L, DIR-868L, and DIR-850L. | |||||
CVE-2016-5800 | 1 Fatek | 2 Automation Fv Designer, Automation Pm Designer V3 | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
A malicious attacker can trigger a remote buffer overflow in the Communication Server in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. | |||||
CVE-2015-1007 | 1 Opto22 | 4 Optodatalink, Optoopcserver, Pac Display and 1 more | 2019-10-09 | 9.3 HIGH | 7.8 HIGH |
A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible. | |||||
CVE-2015-1006 | 1 Opto22 | 4 Optodatalink, Optoopcserver, Pac Display and 1 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
A vulnerable file in Opto 22 PAC Project Professional versions prior to R9.4006, PAC Project Basic versions prior to R9.4006, PAC Display Basic versions prior to R9.4f, PAC Display Professional versions prior to R9.4f, OptoOPCServer versions prior to R9.4c, and OptoDataLink version R9.4d and prior versions that were installed by PAC Project installer, versions prior to R9.4006, is susceptible to a heap-based buffer overflow condition that may allow remote code execution on the target system. Opto 22 suggests upgrading to the new product version as soon as possible. | |||||
CVE-2014-9189 | 1 Honeywell | 1 Experion Process Knowledge System | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version. | |||||
CVE-2017-12194 | 1 Spice-gtk Project | 1 Spice-gtk | 2019-06-17 | 10.0 HIGH | 9.8 CRITICAL |
A flaw was found in the way spice-client processed certain messages sent from the server. An attacker, having control of malicious spice-server, could use this flaw to crash the client or execute arbitrary code with permissions of the user running the client. spice-gtk versions through 0.34 are believed to be vulnerable. | |||||
CVE-2017-13999 | 1 We-con | 1 Levi Studio Hmi Editor | 2018-01-13 | 7.5 HIGH | 9.8 CRITICAL |
A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified in which the application does not verify string size before copying to memory; the attacker may then be able to crash the application or run arbitrary code. | |||||
CVE-2017-13089 | 2 Debian, Gnu | 2 Debian Linux, Wget | 2017-12-30 | 9.3 HIGH | 8.8 HIGH |
The http.c:skip_short_body() function is called in some circumstances, such as when processing redirects. When the response is sent chunked in wget before 1.19.2, the chunk parser uses strtol() to read each chunk's length, but doesn't check that the chunk length is a non-negative number. The code then tries to skip the chunk in pieces of 512 bytes by using the MIN() macro, but ends up passing the negative chunk length to connect.c:fd_read(). As fd_read() takes an int argument, the high 32 bits of the chunk length are discarded, leaving fd_read() with a completely attacker controlled length argument. | |||||
CVE-2017-14016 | 1 Advantech | 1 Webaccess | 2017-12-20 | 6.8 MEDIUM | 6.3 MEDIUM |
A Stack-based Buffer Overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. The application lacks proper validation of the length of user-supplied data prior to copying it to a stack-based buffer, which could allow an attacker to execute arbitrary code under the context of the process. | |||||
CVE-2017-5177 | 1 Vipa Controls | 2 Winplc7, Winplc7 Firmware | 2017-09-16 | 5.0 MEDIUM | 7.5 HIGH |
A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution. |