CVE-2023-39460

Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534.
Configurations

No configuration.

History

No history.

Information

Published : 2024-05-03 03:15

Updated : 2024-05-03 12:50


NVD link : CVE-2023-39460

Mitre link : CVE-2023-39460

CVE.ORG link : CVE-2023-39460


JSON object : View

Products Affected

No product.

CWE
CWE-22

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')