Show plain JSON{"id": "CVE-2023-38680", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}, {"type": "Secondary", "source": "productcert@siemens.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}]}, "published": "2023-08-08T10:15:16.677", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-787"}]}, {"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-787"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)"}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones inferiores a V2201.0008), Tecnomatix Plant Simulation V2302 (Todas las versiones inferiores a V2302.0002). La aplicaci\u00f3n afectada contiene una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado mientras analiza un archivo SPP especialmente dise\u00f1ado. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21132)"}], "lastModified": "2023-08-14T17:16:36.667", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0E8C9093-BD78-4ECE-9221-A889371B3839", "versionEndExcluding": "2201.0008", "versionStartIncluding": "2201"}, {"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C7103507-EE73-42FF-9DAB-37DD06467591", "versionEndExcluding": "2302.0002", "versionStartIncluding": "2302"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}