CVE-2023-31448

A path traversal vulnerability was identified in the HL7 sensor in PRTG 23.2.84.1566 and earlier versions where an authenticated user with write permissions could trick the HL7 sensor into behaving differently for existing files and non-existing files. This made it possible to traverse paths, allowing the sensor to execute files outside the designated custom sensors folder. The severity of this vulnerability is medium and received a score of 4.7 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
Configurations

Configuration 1 (hide)

cpe:2.3:a:paessler:prtg_network_monitor:*:*:*:*:*:*:*:*

History

No history.

Information

Published : 2023-08-09 12:15

Updated : 2023-08-16 12:15


NVD link : CVE-2023-31448

Mitre link : CVE-2023-31448

CVE.ORG link : CVE-2023-31448


JSON object : View

Products Affected

paessler

  • prtg_network_monitor
CWE
CWE-22

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')