Show plain JSON{"id": "CVE-2022-3166", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}, {"type": "Secondary", "source": "PSIRT@rockwellautomation.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2022-12-16T20:15:08.760", "references": [{"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137678", "tags": ["Permissions Required", "Vendor Advisory"], "source": "PSIRT@rockwellautomation.com"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-924"}]}, {"type": "Secondary", "source": "PSIRT@rockwellautomation.com", "description": [{"lang": "en", "value": "CWE-924"}]}], "descriptions": [{"lang": "en", "value": "\nRockwell Automation was made aware that the webservers of the Micrologix 1100 and 1400 controllers contain a vulnerability that may lead to a denial-of-service condition. The security vulnerability could be exploited by an attacker with network access to the affected systems by sending TCP packets to webserver and closing it abruptly which would cause a denial-of-service condition for the web server application on the device\n\n"}, {"lang": "es", "value": "Se inform\u00f3 a Rockwell Automation que los servidores web de los controladores Micrologix 1100 y 1400 contienen una vulnerabilidad que puede provocar una condici\u00f3n de Denegaci\u00f3n de Servicio (DoS). La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados enviando paquetes TCP al servidor web y cerr\u00e1ndolo abruptamente, lo que causar\u00eda una condici\u00f3n de Denegaci\u00f3n de Servicio (DoS) para la aplicaci\u00f3n del servidor web en el dispositivo."}], "lastModified": "2023-11-07T03:50:54.340", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DA42C7F4-EEC1-44D2-BD46-237969FF6E1A"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DCE86CDF-12CC-4B02-942D-BF9134218F2B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "196EA0BE-FDF3-46BE-B3DA-5F49208C5D80"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "11507EFF-5C53-4217-9257-21936118C032"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "PSIRT@rockwellautomation.com"}