Show plain JSON{"id": "CVE-2022-29830", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.1, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.2, "exploitabilityScore": 3.9}, {"type": "Secondary", "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.1, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.2, "exploitabilityScore": 3.9}]}, "published": "2022-11-25T00:15:10.367", "references": [{"url": "https://jvn.jp/vu/JVNVU97244961/index.html", "tags": ["Third Party Advisory", "VDB Entry"], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"}, {"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05", "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"}, {"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf", "tags": ["Mitigation", "Vendor Advisory"], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-798"}]}, {"type": "Secondary", "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "description": [{"lang": "en", "value": "CWE-321"}]}], "descriptions": [{"lang": "en", "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."}, {"lang": "es", "value": "El uso de una vulnerabilidad de clave criptogr\u00e1fica codificada en Mitsubishi Electric GX Works3 en las versiones 1.000A hasta 1.095Z y la configuraci\u00f3n de control de movimiento (software relacionado con GX Works3) de 1.000A y posteriores permite a un atacante remoto no autenticado revelar o alterar informaci\u00f3n sensible. Como resultado, los atacantes no autenticados pueden obtener informaci\u00f3n sobre archivos de proyecto de forma ilegal."}], "lastModified": "2023-06-29T08:15:10.290", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297", "versionEndIncluding": "1.011m", "versionStartIncluding": "1.000a"}, {"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9", "versionEndIncluding": "1.086q", "versionStartIncluding": "1.015r"}, {"criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A", "versionStartIncluding": "1.087r"}], "operator": "OR"}]}], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"}