Show plain JSON{"id": "CVE-2022-29490", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}, {"type": "Secondary", "source": "cybersecurity@hitachienergy.com", "cvssData": {"scope": "CHANGED", "version": "3.1", "baseScore": 8.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "HIGH", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 6.0, "exploitabilityScore": 1.8}]}, "published": "2022-09-12T21:15:10.010", "references": [{"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch", "tags": ["Vendor Advisory"], "source": "cybersecurity@hitachienergy.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "NVD-CWE-Other"}]}, {"type": "Secondary", "source": "cybersecurity@hitachienergy.com", "description": [{"lang": "en", "value": "CWE-285"}]}], "descriptions": [{"lang": "en", "value": "Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*"}, {"lang": "es", "value": "Se presenta una vulnerabilidad de Autorizaci\u00f3n Inapropiada en la WebUI de Workplace X de Hitachi Energy MicroSCADA X SYS600 que permite a un usuario autenticado ejecutar cualquier script interno de MicroSCADA independientemente del rol del usuario autenticado. Este problema afecta: Hitachi Energy MicroSCADA X SYS600 versiones 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*"}], "lastModified": "2023-06-28T20:35:21.053", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0566FCE7-F150-4DEC-A35C-A8A3EBEE8D3D", "versionEndIncluding": "10.3.1", "versionStartIncluding": "10.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@hitachienergy.com"}