Show plain JSON{"id": "CVE-2022-27585", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2022-11-01T21:15:11.683", "references": [{"url": "https://sick.com/psirt", "tags": ["Patch", "Vendor Advisory"], "source": "psirt@sick.de"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-306"}]}, {"type": "Secondary", "source": "psirt@sick.de", "description": [{"lang": "en", "value": "CWE-306"}]}], "descriptions": [{"lang": "en", "value": "Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.6.0 as soon as possible (available in SICK Support Portal)."}, {"lang": "es", "value": "Vulnerabilidad de recuperaci\u00f3n de contrase\u00f1a en SICK SIM1000 FX Partnumber 1097816 y 1097817 con versi\u00f3n de firmware <1.6.0 permite a un atacante remoto sin privilegios obtener acceso al nivel de usuario definido como RecoverableUserLevel invocando el m\u00e9todo del mecanismo de recuperaci\u00f3n de contrase\u00f1a. Esto conduce a un aumento de sus privilegios en el sistema y, por lo tanto, afecta la integridad de la confidencialidad y la disponibilidad del sistema. Un atacante puede esperar un \u00e9xito repetible si explota la vulnerabilidad. La soluci\u00f3n recomendada es actualizar el firmware a una versi\u00f3n >= 1.6.0 lo antes posible (disponible en el Portal de Soporte de SICK)."}], "lastModified": "2023-03-31T16:06:25.677", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:sick:sim1000_fx:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F7D4680F-20B2-4E9E-B2A5-E44F73C6DA3F"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:sick:sim1000_fx_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DBB6C553-9346-435D-9E47-37DA020B0B78", "versionEndExcluding": "1.6.0"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "psirt@sick.de"}