Show plain JSON{"id": "CVE-2022-27194", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 6.9, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2022-04-12T09:15:15.017", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf", "tags": ["Mitigation", "Patch", "Vendor Advisory"], "source": "productcert@siemens.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-400"}]}, {"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-400"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (Consola de Administraci\u00f3n) (todas las versiones anteriores a V3.1 SP1), SINETPLAN (Todas las versiones), TIA Portal (versiones V15, V15.1, V16 y V17). El sistema afectado no puede procesar correctamente los paquetes especialmente dise\u00f1ados enviados al puerto 8888/tcp. Un atacante remoto podr\u00eda aprovechar esta vulnerabilidad para causar una condici\u00f3n de denegaci\u00f3n de servicio. Los dispositivos afectados deben reiniciarse manualmente"}], "lastModified": "2022-04-19T18:28:39.223", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "884EC00C-1155-436D-94F4-C6F2303732CF", "versionEndExcluding": "3.1"}, {"criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:3.1:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "69A8C49A-3AFD-4693-BE59-B3C75D5026E3"}, {"criteria": "cpe:2.3:a:siemens:sinetplan:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "73C56997-3D1D-435A-8B1C-DC1023CE5715"}, {"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A5BC801E-9D78-4CD4-A457-00ABD5991515"}, {"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C36F0E09-C1BB-4ED2-9008-99DC761FDFAA"}, {"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596"}, {"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7E0C3283-1FEA-4054-9D48-5F683FA9E4FF"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}