Show plain JSON{"id": "CVE-2021-40142", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}, {"type": "Secondary", "source": "cve@mitre.org", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2021-08-27T07:15:08.630", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf", "tags": ["Patch", "Third Party Advisory"], "source": "cve@mitre.org"}, {"url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "cve@mitre.org"}, {"url": "https://opcfoundation.org/security-bulletins/", "tags": ["Vendor Advisory"], "source": "cve@mitre.org"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-119"}]}], "descriptions": [{"lang": "en", "value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."}, {"lang": "es", "value": "En OPC Foundation Local Discovery Server (LDS) versiones anteriores a 1.04.402.463, unos atacantes remotos pueden causar una denegaci\u00f3n de servicio (DoS) mediante el env\u00edo de mensajes cuidadosamente dise\u00f1ados que conllevan a el Acceso a una Ubicaci\u00f3n de Memoria Despu\u00e9s del Final de un B\u00fafer."}], "lastModified": "2022-09-03T03:54:54.180", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:opcfoundation:local_discover_server:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2BD47A17-5E0C-4BCA-989C-C5CDEAC20A06", "versionEndExcluding": "1.04.402.463"}], "operator": "OR"}]}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A3BD1C40-AB88-4CB8-820E-C32C4AEBD455", "versionEndExcluding": "2022"}, {"criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:2022:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D113B41E-4268-407B-A729-EBC9385D8943"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "298E8F34-346B-4FC5-8690-3F947F585552"}, {"criteria": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7DF90C44-4AC2-4B2B-8712-30CD3DE96B22"}, {"criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3"}, {"criteria": "cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "AFBD6DDF-917C-44CC-A944-1945DC7AC9FB"}, {"criteria": "cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0F7BB505-A6B6-4200-9602-E4D348E407AB"}, {"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*", "vulnerable": true, "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608"}, {"criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_scada_runtime:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "772ECFF2-BB17-4B72-A570-18631521E147"}, {"criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:3.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "975FC6E7-8FDB-4361-A691-44B26B0CBFD4"}], "operator": "OR"}]}], "sourceIdentifier": "cve@mitre.org"}