Show plain JSON{"id": "CVE-2021-34593", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "info@cert.vde.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}, {"type": "Secondary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2021-10-26T10:15:08.013", "references": [{"url": "http://packetstormsecurity.com/files/164716/CODESYS-2.4.7.0-Denial-Of-Service.html", "tags": ["Exploit", "Third Party Advisory", "VDB Entry"], "source": "info@cert.vde.com"}, {"url": "http://packetstormsecurity.com/files/165874/WAGO-750-8xxx-PLC-Denial-Of-Service-User-Enumeration.html", "tags": ["Exploit", "Third Party Advisory", "VDB Entry"], "source": "info@cert.vde.com"}, {"url": "http://seclists.org/fulldisclosure/2021/Oct/64", "tags": ["Mailing List", "Third Party Advisory"], "source": "info@cert.vde.com"}, {"url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=16877&token=8faab0fc1e069f4edfca5d5aba8146139f67a175&download=", "tags": ["Vendor Advisory"], "source": "info@cert.vde.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "info@cert.vde.com", "description": [{"lang": "en", "value": "CWE-755"}]}], "descriptions": [{"lang": "en", "value": "In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC."}, {"lang": "es", "value": "En CODESYS V2 Runtime Toolkit 32 Bit full y PLCWinNT versiones anteriores a V2.4.7.56, las peticiones no v\u00e1lidas dise\u00f1adas sin autenticaci\u00f3n pueden resultar en varias condiciones de denegaci\u00f3n de servicio. Los programas de PLC en ejecuci\u00f3n pueden detenerse, puede perderse la memoria, o puede bloquearse el acceso de otros clientes de comunicaci\u00f3n al PLC"}], "lastModified": "2022-04-12T18:05:25.237", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:codesys:plcwinnt:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4AD330AD-254E-4E3E-A17E-BE08305AFBA0", "versionEndExcluding": "2.4.7.56"}, {"criteria": "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:x86:*", "vulnerable": true, "matchCriteriaId": "EC36E0FD-2487-4BA0-9EB8-174D30FD4DFB", "versionEndExcluding": "2.4.7.56"}], "operator": "OR"}]}], "sourceIdentifier": "info@cert.vde.com"}