Show plain JSON{"id": "CVE-2021-34308", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 4.3, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.5, "attackVector": "LOCAL", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 1.8}]}, "published": "2021-07-13T11:15:11.510", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-837/", "tags": ["Third Party Advisory", "VDB Entry"], "source": "productcert@siemens.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-125"}]}, {"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-126"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13344)"}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2). La biblioteca BMP_Loader.dll de las aplicaciones afectadas no comprueba apropiadamente los datos suministrados por el usuario cuando se analizan los archivos BMP. Esto podr\u00eda resultar en una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-13344)"}], "lastModified": "2022-10-07T20:47:50.830", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CAFFF33E-9758-4C92-B2BF-2CF0E2EA6217", "versionEndExcluding": "13.2.0"}, {"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6C391214-6E11-4196-BF69-5327069864D8", "versionEndExcluding": "13.2.0"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}