Show plain JSON{"id": "CVE-2021-22765", "cveTags": [{"tags": ["unsupported-when-assigned"], "sourceIdentifier": "cybersecurity@se.com"}], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2021-06-11T16:15:10.457", "references": [{"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03", "tags": ["Vendor Advisory"], "source": "cybersecurity@se.com"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-20"}]}, {"type": "Secondary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-20"}]}], "descriptions": [{"lang": "en", "value": "A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet"}, {"lang": "es", "value": "** NO COMPATIBLE CUANDO SE ASIGN\u00d3 ** UN CWE-20: Se presenta una vulnerabilidad de comprobaci\u00f3n inapropiada de la entrada en PowerLogic EGX100 (versiones 3.0.0 y posteriores) y PowerLogic EGX300 (todas las versiones) que podr\u00eda provocar una denegaci\u00f3n de servicio o una ejecuci\u00f3n de c\u00f3digo remota por medio de un paquete HTTP especialmente dise\u00f1ado"}], "lastModified": "2024-05-17T01:53:54.107", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_egx100_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "29A55C4C-0D14-4C55-ABBC-83280E221DE3", "versionStartIncluding": "3.0.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_egx100:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "FE28A3BC-AD07-48F1-9DB9-65616A9399B5"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_egx300_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9CB9B239-F219-4DF4-B53B-4DCE38F3205F"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_egx300:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "59A033CD-1DBC-44A4-9C56-1F97C3F40C6F"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@se.com"}