Show plain JSON{"id": "CVE-2020-7525", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2020-08-31T17:15:12.547", "references": [{"url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-02/", "tags": ["Vendor Advisory"], "source": "cybersecurity@se.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-307"}]}], "descriptions": [{"lang": "en", "value": "Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used."}, {"lang": "es", "value": "Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de Intentos de Autenticaci\u00f3n Excesivos en todas las versiones de hardware de spaceLYnk y Wiser para KNX (anteriormente homeLYnk) que podr\u00eda permitir a un atacante adivinar una contrase\u00f1a cuando es usado un ataque de fuerza bruta"}], "lastModified": "2020-09-04T18:00:02.220", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FDCD12BD-6A80-41DB-96A8-A3504384A1D8", "versionEndExcluding": "2.5.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F7B2FBBD-C461-47EF-A912-E445C063DED9"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3487CE0B-92B0-4A79-AAEB-ECA9B0876A4E", "versionEndExcluding": "2.5.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "EAF53585-8B87-4609-991E-30B56B601DEA"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@se.com"}