Show plain JSON{"id": "CVE-2018-5472", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": true, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2018-03-26T14:29:00.650", "references": [{"url": "http://www.securityfocus.com/bid/103182", "tags": ["Third Party Advisory", "VDB Entry"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-02", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security", "tags": ["Vendor Advisory"], "source": "ics-cert@hq.dhs.gov"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "NVD-CWE-noinfo"}]}, {"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-264"}]}], "descriptions": [{"lang": "en", "value": "Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code."}, {"lang": "es", "value": "Philips IntelliSpace Portal, en todas las versiones 7.0.x y 8.0.x, contiene una vulnerabilidad de permisos de Windows inseguros que podr\u00eda permitir a un atacante obtener acceso no autorizado y, en algunos casos, escalar su nivel de privilegios o ejecutar c\u00f3digo arbitrario."}], "lastModified": "2019-10-09T23:41:26.377", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:philips:intellispace_portal:8.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "374B9A63-793D-41A1-A02F-4642031DA5FA"}, {"criteria": "cpe:2.3:a:philips:intellispace_portal:9.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "784EBE3C-D9CB-433E-BC1D-4403B3BAB6AA"}], "operator": "OR"}]}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}