Show plain JSON{"id": "CVE-2018-20720", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 6.9, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2019-01-16T03:29:00.237", "references": [{"url": "http://search.abb.com/library/Download.aspx?DocumentID=1MRS758909&LanguageCode=en&DocumentPartId=&Action=Launch", "tags": ["Vendor Advisory"], "source": "cve@mitre.org"}, {"url": "http://www.securityfocus.com/bid/106641", "tags": ["Third Party Advisory", "VDB Entry"], "source": "cve@mitre.org"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-20"}]}], "descriptions": [{"lang": "en", "value": "ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service (reboot) via a reboot command in an SPA message."}, {"lang": "es", "value": "Los dispositivos ABB Relion 630, en versiones 1.1 anteriores a la 1.1.0.C0, versiones 1.2 anteriores a la 1.2.0.B3 y versiones 1.3 anteriores a la 1.3.0.A6, permiten que atacantes remotos provoquen una denegaci\u00f3n de servicio (reinicio) mediante un comando \"reboot\" en un mensaje SPA."}], "lastModified": "2023-05-16T21:02:25.137", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hitachienergy:relion_630_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C9577C39-BDFA-437A-9491-9A42AE894E22", "versionEndExcluding": "1.1.0.c0", "versionStartIncluding": "1.1.0"}, {"criteria": "cpe:2.3:o:hitachienergy:relion_630_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "36DEBA57-8513-4E78-AD39-74A71D41240C", "versionEndExcluding": "1.2.0.b3", "versionStartIncluding": "1.2.0"}, {"criteria": "cpe:2.3:o:hitachienergy:relion_630_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "90BD9672-751F-46B2-BAF9-03B55397D76E", "versionEndExcluding": "1.3.0.a6", "versionStartIncluding": "1.3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hitachienergy:relion_630:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "6E09F1F6-68C9-4B0D-93F2-3D5F528CB2AD"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cve@mitre.org"}