Show plain JSON{"id": "CVE-2018-20114", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 10.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2019-01-02T18:29:01.277", "references": [{"url": "https://github.com/pr0v3rbs/CVE/tree/master/CVE-2018-20114", "tags": ["Exploit"], "source": "cve@mitre.org"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-78"}]}], "descriptions": [{"lang": "en", "value": "On D-Link DIR-818LW Rev.A 2.05.B03 and DIR-860L Rev.B 2.03.B03 devices, unauthenticated remote OS command execution can occur in the soap.cgi service of the cgibin binary via an \"&&\" substring in the service parameter. NOTE: this issue exists because of an incomplete fix for CVE-2018-6530."}, {"lang": "es", "value": "En los dispositivos DIR-818LW Rev.A 2.05.B03 y DIR-860L Rev.B 2.03.B03 de D-Link, la ejecuci\u00f3n remota de comandos del sistema operativo podr\u00eda ocurrir en el servicio de soap.cgi del binario cgibin mediante una subcadena \"\" en el par\u00e1metro \"service\". NOTA: este problema existe debido a una soluci\u00f3n incompleta para CVE-2018-6530."}], "lastModified": "2021-04-23T15:32:49.340", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:dlink:dir-818lw_firmware:2.05.b03:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4349ECC4-5F0F-496C-92E9-39932A40FE8A"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:dlink:dir-818lw:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4725FC82-72B5-4EAB-91C6-D32194C5D4F9"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:dlink:dir-860l_firmware:2.03.b03:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B97322F4-B170-438B-9B20-57D208A2EECF"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:dlink:dir-860l:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "CCDB9720-8F5A-4F02-A436-920CDAC15D69"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cve@mitre.org"}