Show plain JSON{"id": "CVE-2018-11106", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 10.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2020-04-01T17:15:14.737", "references": [{"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051", "source": "a2826606-91e7-4eb6-899e-8484bd4575d5"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-77"}]}], "descriptions": [{"lang": "en", "value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."}, {"lang": "es", "value": "NETGEAR presenta correcciones publicadas para una inyecci\u00f3n de comando previa a la autenticaci\u00f3n en una vulnerabilidad de seguridad del archivo request_handler.php en los siguientes modelos de producto: WC7500, ejecutando versiones de firmware anteriores a 6.5.3.5; WC7520, ejecutando versiones de firmware anteriores a 2.5.0.46; WC7600v1, ejecutando versiones de firmware anteriores a 6.5.3.5; WC7600v2, ejecutando versiones de firmware anteriores a 6.5.3.5; y WC9500, ejecutando versiones de firmware anteriores a 6.5.3.5."}], "lastModified": "2023-11-07T02:51:37.613", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8184DF48-1CCE-4950-921B-8A825D8CDD71", "versionEndExcluding": "6.5.3.5"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wc7520_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "86CD35ED-0A90-4932-976B-A7666B3D7C7A", "versionEndExcluding": "2.5.0.46"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wc7520:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A58C9FE8-4BD5-41F9-9714-2D8083A51D98"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wc7600v1_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "3D3D43A9-6A00-4498-BEC5-46A11604A1A6", "versionEndExcluding": "6.5.3.5"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wc7600v1:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8EB1A3EC-1069-40FC-BDDF-C3AC93E037C5"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "EB9D9CAF-D9FC-4E42-9C80-DE53C75AD578", "versionEndExcluding": "6.5.3.5"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "4C8BB1F1-A12D-43CC-A6D0-9633E99D746B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8073AB91-0F60-4EF8-9347-EB0EA6C76A76", "versionEndExcluding": "6.5.3.5"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "113D0DF6-C719-4A43-80B2-463EC4323009"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "a2826606-91e7-4eb6-899e-8484bd4575d5"}