Show plain JSON{"id": "CVE-2011-4036", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}]}, "published": "2011-12-02T11:55:05.607", "references": [{"url": "http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695", "source": "cret@cert.org"}, {"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page", "source": "cret@cert.org"}, {"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf", "tags": ["US Government Resource"], "source": "cret@cert.org"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-22"}]}], "descriptions": [{"lang": "en", "value": "Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors."}, {"lang": "es", "value": "Vulnerabilidad de salto de directorio en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores permite a atacantes remotos leer ficheros arbitrarios a trav\u00e9s de vectores no especificados."}], "lastModified": "2011-12-02T11:55:05.607", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FA173AD2-52AF-4401-9A29-757B68168B4D", "versionEndIncluding": "4.30"}, {"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "00E3E11B-E433-4D89-9525-8159CEC30DC0"}, {"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2788D1E5-206A-4AC8-AA28-65E5EE268B59"}, {"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "99B88BED-7F2F-4F89-9BD1-B7EDC1608531"}], "operator": "OR"}]}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "859A64AD-1FB2-4A7C-AE4D-26951FC050F9", "versionEndIncluding": "4.30"}, {"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B491E331-B533-4E09-966E-45A3BE724C5A"}], "operator": "OR"}]}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "106C6198-C341-4B10-8788-A8FA51F137F1", "versionEndIncluding": "4.10"}, {"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "38765B0B-9C09-4BC0-9E50-D0C6E8969A77"}], "operator": "OR"}]}], "sourceIdentifier": "cret@cert.org"}